[Contents] [Prev] [Next] [Index] [Report an Error]

Defining an Alarm for an SNMP Monitor That Compares Object Values (SRC CLI)

You can configure a monitor to compare a sample value to a specified value or range of values by using one of the following types of comparisons:

Note: Configure only one monitor test at a time.

Before you define an alarm type, configure the associated SNMP alarm.

See Configuring an SNMP Alarm on a C Series Controller (SRC CLI).

To configure a monitor to compare a sample to a specified value or range of values:

  1. From configuration mode, access the configuration statements that configure SNMP monitoring for a boolean test. For example:
    [edit]
    user@host# edit snmp monitor alarm saeHeapUsage boolean-test

    where saeHeapUsage is the name of the alarm.

  2. Specify the type of boolean test. For example:
    [edit snmp monitor alarm saeHeapUsage boolean-test]
    user@host# set comparison greater
  3. Define the value that the test uses. For example:
    [edit snmp monitor saeHeapUsage boolean-test]
    user@host# value 14000000

Related Topics


[Contents] [Prev] [Next] [Index] [Report an Error]