[Contents] [Prev] [Next] [Index] [Report an Error]

Viewing Power Status of a Controller Using IPMI

You can view IPMI power information for the controller you are currently logged on to and for a remote controller. You must be logged in as a root user.

To display power status (on or off) of the local controller using IPMI:

  1. Log in as root user.
    SRC-PE Release 3.1 [R.3.1.0-12]
    login: root
  2. Enter the password.
    Password: password
    --- SRC CLI 3.1 build CLI.R.3.1.0.012
    (c) 2005-2008 Juniper Networks Inc.
    root@host>

    You are now logged in as root user.

  3. Enter the show ipmi power command.

    For example:


    root@host>show ipmi power
    Chassis Power is on

To display power status information on a remote controller using IPMI:

  1. Log in as root user.
  2. Enter the show ipmi host power command.
    root@host>show ipmi host host user user power

    For example:

    root@host>show ipmi host 10.10.10.30 user johndoe power

[Contents] [Prev] [Next] [Index] [Report an Error]