You can view IPMI chassis information for the controller you are currently logged in to and for a remote controller. You must be logged on as a root user.
To display the chassis information on the local controller using IPMI:
- SRC-PE Release 3.1 [R.3.1.0-12]
- login: root
- Password: password
- --- SRC CLI 3.1 build CLI.R.3.1.0.012
- (c) 2005-2008 Juniper Networks Inc.
- root@host>
You are now logged in as root user.
For example:
root@host>show ipmi chassis
System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : always-off Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false
System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : always-off Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false
To display the IPMI chassis information on a remote controller:
- user@host>show ipmi host host user user chassis
For example:
- root@host>show ipmi host 10.10.10.30 user
johndoe chassis