Use the following configuration statement to configure the application manager–to–policy server interface (PKT-MM3) so that the policy server can communicate with application managers:
- slot number jps am-interface {
- pep-id pep-id;
- listening-address listening-address;
- validate-pcmm-objects;
- message-max-length message-max-length;
- message-read-buffer-size message-read-buffer-size;
- message-write-buffer-size message-write-buffer-size;
- open-connection-timeout open-connection-timeout;
- }
To configure the connections to the application managers:
- user@host# edit slot 0 jps am-interface
- [edit slot 0 jps am-interface]
- user@host# set pep-id pep-id
Changes apply only to COPS connections that are established after you make the change.
- [edit slot 0 jps am-interface]
- user@host# set listening-address listening-address
Changes take effect only after you restart the JPS (see Restarting the JPS).
- [edit slot 0 jps am-interface]
- user@host# set validate-pcmm-objects
- [edit slot 0 jps am-interface]
- user@host# set message-max-length message-max-length
- [edit slot 0 jps am-interface]
- user@host# set message-read-buffer-size message-read-buffer-size
- [edit slot 0 jps am-interface]
- user@host# set message-write-buffer-size message-write-buffer-size
- [edit slot 0 jps am-interface]
- user@host# set open-connection-timeout open-connection-timeout
The connection is dropped when initial PCMM messages are not exchanged within this time period.
[edit slot 0 jps am-interface] user@host# show pep-id SDX-JPS; listening-address ; validate-pcmm-objects; message-max-length 204800; message-read-buffer-size 1000000; message-write-buffer-size 1000000; open-connection-timeout 5;