| Weight |
33 lb (15 kg)
|
| Dimensions |
3.5 (H) x 16.7 (W) x 16.2 (D) inches8.89 (H) x 42.42
(W) x 41.15 (D) cm
|
| Environmental Requirements
|
|
|
Temperature
|
- Operating: 50° to 104° F (10° to 40° C)
- Storage: –40° to 158° F (–40° ˚ to
70° C)
|
|
Relative humidity
|
- Operating: 8% to 90% (noncondensing)
- Storage: 5% to 95% (noncondensing)
|
| Heat Dissipation
|
500 W, 1706 BTU/hour maximum
|
| AC Input |
|
|
Power required
|
100-240 VAC @ –5 A
|
|
AC line frequency
|
50-60 Hz
|
|
Power
|
500 W
|
| Space Requirements
|
- 3 feet (90 cm) behind system or rack
- Do not block air vents on front or back of the system
|
| Airflow |
- Air intake occurs in the front and of the system.
- Air is exhausted out of the rear of the system.
|
| Electromagnetic Emissions Agency
Certification
|
|