[Contents]
[Prev]
[Next]
[Index]
[Report an Error]
Monitoring Interfaces
From User Exec mode, use the following show commands to monitor and display the T3 or E3 interface
information:
- host1#show controllers t3 0/1
- host1#show controllers e3 3/2
Setting a Baseline
You can set a statistics baseline for serial interfaces
using the baseline interface serial command. Use the delta keyword with the show commands to display
statistics with the baseline subtracted.
Displaying Counters and Time Intervals
Counters and time intervals are MIB statistics,
which are defined in
RFC 2496—Definitions of
Managed Objects for the DS3/E3 Interface Types (January 1999).
The show controllers t3 slot/port all command displays the following interface information:
- Status information
- T3 current interval counters—Displays the counters
for the current interval
- T3 last interval counters—Displays the counters
for the previous interval
- T3 24-hour total counters—Displays the cumulative
counters for the last 24-hours or since the interface was started
- The last 24-hours of 15-minute reporting intervals (96
intervals)
The show controllers e3 slot/port all command displays identical information for an E3 controller (except
where noted).
Output Filtering
You can use the output filtering feature of the show command to include or exclude lines of output
based on a text string you specify. See Command Line Interface in JUNOSe System Basics Configuration Guide.
baseline interface
- Use to set a statistics baseline for serial interfaces.
- The router implements the baseline by reading and storing
the statistics at the time the baseline is set and then subtracting
this baseline whenever baseline-relative statistics are retrieved.
- Use the optional delta keyword
with the show interfaces serial commands
to view the baseline statistics.
- Example
- host1#baseline interface serial 2/0
- There is no no version.
- See baseline interface.
show controllers e3
show controllers t3
- Use to display the parameters and MIB statistics on an
interface.
- Use the brief keyword to display
the administrative and operational status of all configured T3 or
E3 interfaces, or to display abbreviated information for the specified
T3 or E3 interface.
- For definitions of the MIB statistics, see RFC 2496—Definitions
of Managed Objects for the DS3/E3 Interface Types (January 1999)
- Field descriptions
- Description—Text description or alias if configured
for the interface
- ifAdminStatus—One of the following administrative
states of the interface:
- ifAdminUp—Interface is administratively enabled
- ifAdminDown—Interface is administratively disabled
- ifAdminTesting—Interface is administratively configured
in a testing state
- snmp trap link-status—Status of SNMP trapping (enabled
or disabled)
- alarms detected—One of the following T3 alarms (not
applicable for E3):
- No alarm present—No alarms present on the line
- Rcv RAI Failure—Remote device is sending a far end
alarm failure
- Xmt RAI Failure—Local device is sending a far end
alarm failure
- Rcv AIS—Remote device is sending an alarm indication
signal (AIS)
- Xmt AIS—Local device is sending an AIS
- Rcv LOF—Loss of one or more frames from the remote
end
- Rcv LOS—Loss of signal at the local end
 |
Note:
The alarms detected field does not appear for interfaces that
you disabled in the software.
|
- framing—Type of framing format
- line code—Type of line code format
- clock source—Type of clock source
- cable length—Cable length, in feet (this field is
not present for E3 controllers)
- Loopback—State of loopback for the controller: enabled
or disabled. If loopback is enabled, one of the following states is
displayed:
- Diagnostic—Data loops back toward the router and
sends an alarm AIS toward the network
- Payload—Data loops toward the network after the
framer has processed the data
- Line—Data loops toward the network before the data
reaches the framer
- loopback state—State of loopback for the controller:
enabled or disabled
- DSU mode—Mode of the fractional T3 lines: Digital
Link mode or Larscom mode
- DSU bandwidth—Speed of the fractional T3 lines
- DSU scramble—Status of scrambling for fractional
T3: on or off
- MDL Transmit Path—Indicates whether the transmission
is active or not active (T3 only)
- MDL Transmit Test-Signal—Indicates if the transmission
is active or not active (T3 only)
- MDL Transmit Idle-Signal—Indicates if the transmission
is active or not active (T3 only)
- Equipment Identification Code—eic string for MDL
(T3 only)
- Line Identification Code—lic string for MDL (T3
only)
- Frame Identification Code—fic string for MDL (T3
only)
- Facility Identification Code—fic string for MDL
(T3 only)
- Equipment Port—port string for MDL (T3 only)
- Unit Identification Code—unit string for MDL (T3
only)
- Facility Identification Code—pfi string for MDL
(T3 only)
- Port Code—port string for MDL (T3 only)
- Generator Number—generator string for MDL (T3 only)
- BERT test—Number of current test and total number
of tests (T3 only)
- Test interval—Length of the BERT test
- status—Sync (controller is synchronized with remote
device) or NoSync (controller is not synchronized with remote device)
- Sync count—Number of times the pattern detector
synchronized with the incoming data pattern
- Received bit count—Number of bits received
- Error bit count—Number of bits with errors
- Number of valid intervals—Number of 15-minute intervals
since the T3 or E3 module was last powered on or reset
- Time elapse in current interval—Number of seconds
that have passed in the 15-minute (900 second) interval
- Errored seconds—Number of errored seconds encountered
by an E3 (not applicable for T3) in the current interval (this field
is not present for T3 controllers)
- P-bit errored seconds—Number of errored seconds
encountered by a T3 (not applicable for E3) in the current interval
(this field is not present for E3 controllers)
- Severely errored seconds—Number of severely errored
seconds encountered by an E3 (not applicable for T3) in the current
interval (this field is not present for T3 controllers)
- P-bit severely errored seconds—Number of severely
errored seconds encountered by a T3 (not applicable for E3) in the
current interval (this field is not present for E3 controllers)
- Severely errored frame seconds—Number of severely
errored framing seconds encountered by a T3 or E3 in the current interval
- Unavailable seconds—Number of unavailable seconds
encountered by a T3 or E3 in the current interval
- Line code violations—Number of line code violations
encountered by a T3 or E3 in the current interval
- P-bit coding violations—Number of coding violations
encountered by a T3 (not applicable for E3) in the current interval
(this field is not present for E3 controllers)
- Coding violations—Number of coding violations encountered
by an E3 (not applicable for T3) in the current interval (this field
is not present for T3 controllers)
- Line errored seconds—Number of line errored seconds
encountered by a T3 or E3 in the current interval
- C-bit coding violations—Number of C-bit coding violations
encountered by a T3 (not applicable for E3) in the current interval
(this field is not present for E3 controllers)
- C-bit errored seconds—Number of C-bit errored seconds
encountered by a T3 (not applicable for E3) in the current interval
(this field is not present for E3 controllers)
- C-bit severely errored seconds—Number of C-bit severely
errored seconds encountered by a T3 (not applicable for E3) in the
current interval (this field is not present for E3 controllers)
- Example 1
host1#show controllers t3 2/0
DS3 2/0
Description: boston09 hdlc channel
ifAdminStatus = ifAdminDown
snmp trap link-status = enabled
No alarms detected
Framing is C-BIT, Line Code is B3ZS, Clock Source is Line
Cable Length is 0 ft
Loopback Disabled
DSU Mode is Larscom
DSU Bandwidth is 4000
DSU Scrambler is off
MDL Transmit Path is not active
MDL Transmit Test-Signal is active
MDL Transmit Idle-Signal is not active
Equipment Identification Code is ERX-1400
Line Identification Code is Bldg 10
Frame Identification Code is null string
Unit Identification Code is 080001
Facility Identification Code is Site 25
Port Code is Port 0800
Generator Number is null string
Number of valid interval - 96
Time elapse in current interval - 861
Ds3 Current Interval Counters
P-bit errored seconds = 0
P-bit severely errored seconds = 0
Severely errored frame seconds = 0
Unavailable seconds = 0
Line code violations = 0
P-bit coding violations = 0
Line errored seconds = 0
C-bit coding violations = 0
C-bit errored seconds = 0
C-bit severely errored seconds = 0
Ds3 Last Interval Counters
P-bit errored seconds = 0
P-bit severely errored seconds = 0
Severely errored frame seconds = 0
Unavailable seconds = 0
Line code violations = 0
P-bit coding violations = 0
Line errored seconds = 0
C-bit coding violations = 0
C-bit errored seconds = 0
C-bit severely errored seconds = 0
Ds3 24 Hour Total Counters
P-bit errored seconds = 0
P-bit severely errored seconds = 0
Severely errored frame seconds = 0
Unavailable seconds = 0
Line code violations = 0
P-bit coding violations = 0
Line errored seconds = 0
C-bit coding violations = 0
C-bit errored seconds = 0
C-bit severely errored seconds = 0
- Example 2—In this example, the brief keyword is specified.
host1#show controllers t3 brief
Interfaces ifAdminStatus OperationalStatus
5/0(channelized) up up
5/1(channelized) up up
5/2(channelized) up down
5/3(channelized) down down
5/4(channelized) down down
5/5(channelized) down down
5/6(channelized) down down
5/7(channelized) down down
5/8(channelized) down down
5/9(channelized) down down
5/10(channelized) down down
5/11(channelized) down down
3/0(channelized) down down
3/1(channelized) down down
3/2(channelized) down down
4/0:1/1(unchannelized) up down
4/2:1/1(channelized) up lowerLayerDown
- See show controllers e3.
- See show controllers t3.
show controllers t3 remote
- Use to display MIB statistics for the remote end of a
T3 interface configured for MDL.
- Specify the all option to display
detailed information for all 15-minute intervals.
- For definitions of the MIB statistics for a T3 interface,
see RFC 2496—Definitions of Managed Objects for the DS3/E3 Interface
Types (January 1999).
- Field descriptions
- Far End MDL Carrier bit—Status of MDL configuration
on remote device connected to T3 interface
- set—MDL is configured for carrier mode
- not set—MDL is not configured for carrier mode
- Far End Equipment Identification Code—eic string
sent by remote device for MDL
- Far End Line Identification Code—lic string sent
by remote device for MDL
- Far End Frame Identification Code—fic string sent
by remote device for MDL
- Far End Unit Identification Code—unit string sent
by remote device for MDL
- Far End Facility Identification Code—pfi string
sent by remote device for MDL
- Far End Generator Number—generator string sent by
remote device for MDL
- Far End Port Number—port string sent by remote device
for MDL
- Number of valid intervals—Number of 15-minute intervals
since the line module was last powered on or reset
- Time elapse in current interval—Number of seconds
that have passed in the 15-minute (900-second) interval
- C-bit errored seconds—Number of C-bit errored seconds
encountered by a T3 in the current interval
- C-bit severely errored seconds—Number of C-bit severely
errored seconds encountered by a T3 in the current interval
- C-bit coding violations—Number of C-bit coding violations
encountered by a T3 in the current interval
- Unavailable seconds—Number of unavailable seconds
encountered by a T3 in the current interval
- Invalid seconds—Number of seconds when statistics
were not collected
- Example—This example specifies a T3 interface.
host1#show controllers t3 5/0 remote
Far End MDL Carrier bit is not set
Far End Equipment Identification Code is the null string
Far End Line Identification Code is the null string
Far End Frame Identification Code is the null string
Far End Unit Identification Code is the null string
Far End Facility Identification Code is the null string
Far End Generator Number is the null string
Far End Port Number is the null string
Number of valid interval - 3
Time elapse in current interval - 756
Ds3 Current Interval Counters
C-bit errored seconds = 0
C-bit severely errored seconds = 0
C-bit coding violations = 0
Unavailable seconds = 0
Invalid seconds = 0
Ds3 Last Interval Counters
C-bit errored seconds = 0
C-bit severely errored seconds = 0
C-bit coding violations = 0
Unavailable seconds = 0
Invalid seconds = 0
Ds3 24 Hour Total Counters
C-bit errored seconds = 1
C-bit severely errored seconds = 1
C-bit coding violations = 330
Unavailable seconds = 0
Invalid seconds = 0
- See show controllers t3 remote.
[Contents]
[Prev]