Before You Configure an Interface
Before you configure a channelized T3 interface,
verify the following:
- You have installed the line module and the I/O module
correctly.
- Each configured line module is able to transmit data to
and receive data from your switch connections.
For more information about installing line modules
and I/O modules, see the ERX Hardware
Guide.
You should also have the following information
available:
- Framing type, clock source, cable length, and the loopback
method for each T3 controller
- Framing type and clock source for each T1 channel
- Timeslot mapping and line speed for each fractional T1
channel
- HDLC channel information, such as data inversion information,
cyclic redundancy check (CRC) type, idle character, maximum transmission
unit (MTU), and maximum receive unit (MRU)