You can configure MLPPP interfaces on the following E-series routers:
For information about the modules that support MLPPP interfaces on ERX-14xx models, ERX-7xx models, and the ERX-310 router:
For information about the modules that support MLPPP interfaces on the E120 router and the E320 router:
Some of the configuration task examples in this chapter use the slot/port format to specify the physical interface on which you want to configure MLPPP. However, the interface specifier format that you use depends on the type of physical interface on which you want to configure MLPPP and on the router that you are using.
For ERX-7xx models, ERX-14xx models, and ERX-310 routers, use the slot/port format. For example, the following command specifies an ATM interface on slot 5, port 1 of an ERX-7xx model, ERX-14xx model, or ERX-310 router.
- host1(config)#interface atm 5/1
For E120 and E320 routers, use the slot/adapter/port format, which includes an identifier for the bay in which the I/O adapter (IOA) resides. In the software, adapter 0 identifies the right IOA bay (E120 router) and the upper IOA bay (E320 router); adapter 1 identifies the left IOA bay (E120 router) and the lower IOA bay (E320 router). For example, the following command specifies a tunnel-server port on slot 3, adapter 0, port 0 of an E320 router.
- host1(config)#tunnel-server 3/0/0
For more information about supported interface types and specifiers on E-series routers, see Interface Types and Specifiers.