You can configure 802.3ad link aggregation on the following E-series routers:
For information about the modules that support 802.3ad link aggregation on ERX-14xx models, ERX-7xx models, and the ERX-310 router:
For information about the modules that support 802.3ad link aggregation on the E120 router and the E320 router:
The configuration task examples in this chapter use the format for ERX-7xx models, ERX-14xx models, and the ERX-310 router to specify 802.3ad link aggregation.
For example, the following command specifies a Gigabit Ethernet interface on port 0 of an I/O module in slot 4.
- host1(config)#interface gigabitEthernet 4/0
When you configure a Gigabit Ethernet interface or a 10-Gigabit Ethernet interface on E120 or E320 routers, you must include the adapter identifier as part of the interface specifier. For example, the following command specifies a Gigabit Ethernet interface on port 0 of the IOA installed in the upper adapter bay of slot 3.
- host1(config)#interface gigabitEthernet 3/0/0
For more information about interface types and specifiers on E-series models, see Interface Types and Specifiers.