| Line module label | OCx/STMx ATM or OCx/STMx
/DS3-ATM |
| I/O module label | OC12 STM4 I/O
SINGLE MODE |
| Number of I/O ports |
|
| Software release |
-
First supported: 5.0.0, 5.3.0 or a higher-numbered release
-
Final supported: Not applicable
|
| Description |
-
130 W
-
256 MB of memory
-
The 128-MB version has reached end-of-life.
-
Unchannelized, concatenated OC12/STM4 for ATM
|
| Type |
|
| Capability |
|
| Software features |
-
See OCx/STMx ATM Modules for information
about the layer 2 and layer 3 protocols and applications that this
module combination supports.
|
| Model compatibility |
-
ERX-7xx models
-
ERX-14xx models
-
ERX-310 router
|
| SRP module compatibility |
-
SRP-5G+
-
SRP-10G
-
SRP-40G
-
SRP-40G PLUS
-
SRP-SE10G
|
| Module redundancy support |
-
1:N redundancy
-
NOTE: Line module redundancy
is not supported on the ERX-310 router.
|
| Cables and connectors |
-
SC full duplex
-
Tx power:
-
Center wavelength: 1310 nm
-
Rx input power:
-
Rated for 15 km (9.3 miles) of 9-micron core cable
-
See ERX Hardware Guide, Chapter 5, Cabling
ERX Routers for more information.
|
| LEDs |
|
| Alarms, errors, and events |
-
See Monitoring SONET/SDH Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 3,
Configuring Unchannelized OCx/STMx Interfaces.
|