resource if-type
Specifies threshold values for specific interface types on a slot or systemwide basis. The no version sets the threshold parameter to its default value (for rising, 90% of the maximum value of the resource; for falling, 1% of the maximum value of the resource; for hold-down time, 300 seconds).
CAUTION: Do not specify a falling value larger than the specified rising value; do not specify a rising value smaller than the specified falling value.
[ no ] resource if-type { atm-active-sub-if | atm-sub-if | atm-vc | ip | ppp-link }
{ slot slot | system }
threshold { falling fallingValue | hold-down-time holdDownTime | rising risingValue }
- atm-active-sub-ifConfigures active ATM subinterfaces
- atm-sub-ifConfigures both active and inactive ATM subinterfaces
- atm-vcConfigures ATM virtual circuits
- ipConfigures IP interfaces
- ppp-linkConfigures PPP link interfaces
- slotNumber of the chassis slot in the range 02 (ERX-310 model), 06 (ERX-7xx models), 013 (ERX-14xx models), 05 (E120 router), and 0-16 (E320 router)
- For ERX-7xx models, a number in the range 06; for ERX-14xx models, a number in the range 013; for the ERX-310 router, a number in the range 12; for the E120 router, a number in the range 05; for the E320 router, a number in the range 016
- fallingValueFalling threshold for the resource, in the range 04294967295
- holdDownTimeHold-down time for the resource, in the range 04294967295 seconds
- risingValueRising threshold for the resource, in the range 04294967295
Global Configuration
Command introduced before JUNOSe Release 7.1.0.