Enabling Warm Restart Diagnostics on Modules

You can enable the system to perform diagnostic tests on SRP modules and line modules when the specified module is warm restarted. The system performs all the diagnostic tests that normally run when the module is cold started.

SRP modules on all E-series routers support warm restart diagnostics. Table 44 lists the line modules that support warm restart diagnostics.

Table 44: Supported Line Modules
Line Module

cOCx FO

CT3/T3-F0

OCx/STMx ATM

GE/FE

GE-2

GE-HDE

OC3/STM1 GE/FE

OC48

ES2 4G LM

ES2 10G Uplink LM


The number of diagnostic tests that the system performs on line modules depends on whether you have configured line module redundancy. If you enable warm restart diagnostics on the spare line module when all other line modules are active, the system performs diagnostic tests on the spare line module including the spare I/O module.

Enabling warm restart diagnostics on a primary line module forces the line module to switch over to the spare line module.

To ensure complete diagnostic test coverage, we recommend that you disable line module redundancy using the redundancy lockout command before enabling warm restart diagnostics.

Enabling Warm Restart Diagnostics

Use the diag command to enable warm restart diagnostics on a module.

diag