path ds1 fdl string
Defines an FDL message for a DS1 signal, as defined in the ANSI T1.403 specification. This command applies to a DS1 over channelized SONET or SDH interface. Currently, FDL strings can only be configured locally. The no version restores the default value to the specified FDL message or to all FDL messages.
path pathChannel ds1 tributaryIdentifier fdl string { eic eicValue | fic ficValue |
lic licValue | unit unitValue | pfi pfiValue | port portValue | generator generatorValue }no path pathChannel ds1 tributaryIdentifier fdl string { eic | fic | lic | unit | pfi | port |
generator }
- pathChannelNumber, in the range 12147483648, that identifies the path
- tributaryIdentifierIdentifier for the tributary. See description for the path ds1|e1 command.
- eicValueEquipment identification code; 110 characters; default value is the null value
- ficValueFrame identification code; 110 characters; default value is the null value
- licValueLine identification code; 110 characters; default value is the null value
- unitValueUnit identification code; 16 characters; default value is the null value.
- pfiValueFacility identification code to send in the FDL path message; 138 characters; default value is the null value
- portValueEquipment port number to send in the FDL idle signal message; 138 characters; default value is the null value
- generatorValueGenerator number to send in the FDL test signal message; 138 characters; default value is the null value
Controller Configuration
Command introduced before JUNOSe Release 7.1.0.