path ds1|e1 bert
Enables bit error rate tests using the specified pattern at the DS1/E1 over SONET/SDH VT layer on channelized SONET and SDH interfaces. The no version stops the test that is running.
path pathChannel { ds1 | e1 } tributaryIdentifier bert
pattern pattern interval time [ unframed ]no path pathChannel { ds1 | e1 } tributaryIdentifier bert
- pathChannelNumber, in the range 12147483648, that identifies the path
- tributaryIdentifierIdentifier for the tributary. See description for the path ds1|e1 command.
- patternOne of the following test patterns:
- 2^11Pseudorandom test pattern, 2,047 bits long
- 2^15Pseudorandom test pattern, 32,767 bits long
- 2^20-O153Pseudorandom test pattern, 1,048,575 bits long
- timeDuration of the test, in the range 11440 minutes
- unframedTest bit pattern occupies all bits on the link, overwriting the framing bits. If you do not specify this keyword, the test bit pattern occupies only T1/E1 payload bits.
Controller Configuration
Command introduced before JUNOSe Release 7.1.0.