frame-relay lmi-n392dce
Sets the error threshold counter (N392) on a DCE interface. The no version removes current setting and sets the default.
frame-relay lmi-n392dce threshold
- thresholdPositive number in the range 1 10; number of errors that will place the interface in an operationally down state; default value is 2 errors
Interface Configuration
Release Information Command introduced before JUNOSe Release 7.1.0.