bert
Enables bit error rate tests using the specified pattern on T3 interfaces on channelized and unchannelized T3 modules. The no version stops the test that is running.
NOTE: The BERT patterns supported can vary depending on the line module and I/O module assembly you are using.
bert pattern pattern interval time [ unframed ]
- 0sRepetitive test pattern of all zeros, 00000...
- 1sRepetitive test pattern of all ones, 11111...
- 2^9Pseudorandom test pattern, 511 bits in length
- 2^11Pseudorandom test pattern, 2047 bits in length
- 2^15Pseudorandom test pattern, 32,767 bits in length
- 2^20-O153Pseudorandom test pattern, 1,048,575 bits in length
- 2^20-QRSSPseudorandom QRSS test pattern, 1,048,575 bits in length
- 2^23Pseudorandom test pattern, 8,388,607 bits in length
- alt-0-1Repetitive alternating test pattern of zeros and ones, 01010101...
- timeDuration of the test in the range 11440 minutes
- unframed(available for E1 and T1 interfaces only) if specified, the test bit pattern occupies all bits on the link, overwriting the framing bits; if not specified, the test bit pattern occupies only the payload bits
Controller Configuration
Release Information Command introduced before JUNOSe Release 7.1.0.