atm lbo
Specifies the cable length (line build-out) for the ATM T3 or E3 interface. The length of cable determines power requirements. The no version restores the default value.
atm lbo { long | short }
- longSpecifies cable length in the range 226450 feet
- shortSpecifies cable length in the range 0225 feet (the default)
Interface Configuration
Release Information Command introduced before JUNOSe Release 7.1.0.