| Line module label | OCx/STMx ATM or OCx/STMx
/DS3-ATM |
| I/O module label | 4XOC3
APS I/O
MULTI MODE |
| Number of I/O ports |
|
| Software release |
-
First supported: 5.1.2, 5.2.0 (APS/MSP)
-
Final supported: Not applicable
-
The OCx/STMx ATM line module or the OCx/STMx /DS3-ATM
line module must have a minimum of 256 MB of memory to be used with
JUNOSe Release 5.3.0 or a higher-numbered release.
|
| Description |
-
130 W
-
Can use either the 128-MB OCx/STMx ATM line module or
the 256-MB OCx/STMx /DS3-ATM line module.
-
Unchannelized, concatenated OC3/STM1 for ATM
|
| Type |
|
| Capability |
|
| Software features |
-
See OCx/STMx ATM Modules for information
about the layer 2 and layer 3 protocols and applications that this
module combination supports.
|
| Model compatibility |
-
ERX-7xx models
-
ERX-14xx models
-
ERX-310 router
|
| SRP module compatibility |
-
SRP-5G+
-
SRP-10G
-
SRP-40G
-
SRP-40G PLUS
-
SRP-SE10G
|
| Module redundancy support |
-
1:N redundancy
-
NOTE: Line module redundancy
is not supported on the ERX-310 router.
|
| Cables and connectors |
-
LC full duplex
-
Tx power:
-
min: –19 dBm
-
max: –14 dBm
-
Center wavelength: 1310 nm
-
Rx input power:
-
min: –30 dBm
-
max: –14 dBm
-
Rated for 2 km (1.2 miles) over 62.5-micron core cable
with an optical loss of 0–9 dB or 50-micron core cable with
an optical loss of 7 dB
-
See ERX Hardware Guide, Chapter 5, Cabling
ERX Routers for more information.
|
| LEDs |
|
| Alarms, errors, and events |
-
See Monitoring SONET/SDH Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 3,
Configuring Unchannelized OCx/STMx Interfaces.
|