| Weight | |
|
Chassis only
|
51 lb (23.1kg)
|
|
Chassis fully configured
|
Approximately 107 lb (48.5 kg)
|
| Dimensions | |
|
Chassis only
|
11.25 (H) x 17.45 (W) x 25.10 (D) inches; 28.57 x 44.32 x 63.75
cm
|
| Environmental Requirements |
Pending
|
|
Ambient operating temperature
|
- Long term: 41° to 104° F (5° to 40° C)
- Short term: 23° to 122° F (–5° ˚
to 50° C)
|
|
Ambient operating humidity
|
- Long term: 5% to 85% (noncondensing)
- Short term: 5% to 95% (noncondensing)
|
|
Ambient storage temperature
|
–40° ˚ to 158° F (–40° ˚ to
70° C), 95% relative humidity
|
|
Ambient storage humidity
|
5% to 95% (noncondensing)
|
| Heat Dissipation |
1920 W, 6553 BTU/hour maximum
|
| DC Input | |
|
Voltage
|
–40 to –72 VDC
NOTE: If the voltage rises above
–40 VDC, the system powers off. The system does not power on
again until the input voltage reaches –43 +/– 0.5 VDC.
|
|
Current
|
40 A @ –48 VDC
|
|
Power
|
1920 W
|
|
Redundancy (input power)
|
2 independent line feeds
|
| Space Requirements |
- 3 feet (90 cm) behind router or rack
- Do not block air vents on sides of the router
- Do not place equipment that exhausts hot air to left on
the right of the router.
|
| Airflow |
- Air intake occurs from the right side of the router.
- Air is exhausted out of the left side of the router.
|
| NEBS Certification Level
3 |
Pending
|
| Safety Agency Certification |
- AS/NZS 60950:2000 Safety of Information Technology Equipment
- CAN/CSA-C22.2, No. 60950-1–03, First Edition, Information
Technology Equipment - Safety - Part 1: General Requirements
- EN60825-1, Safety of Laser Products - Part 1: Equipment
Class, Requirements, and User's Guide (2001)
- EN 60950-1:2001, First Edition, Information Technology
Equipment - Safety - Part 1: General Requirements
- IEC 60950-1(2001-10) Ed. 1.0 Information Technology Equipment
- Safety - Part 1: General Requirements
- Low Voltage Directive (73/23/EEC)
- UL 60950-1, First Edition, Information Technology Equipment
- Safety - Part 1: General Requirements
|
| Electromagnetic Emissions
Agency Certification |
- AS/NZS CISPR 22:2004
- EMC Directive (89/336/EEC)
- EN 300 132–2 (Narrowband and Wideband)
- EN55022 Class A (CISPR-22 Class A)
- EN55024, Annex C for WAN Equipment Performance Criteria
A, B, and C
- EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6
- ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic
Compatibility (EMC) requirements
- FCC Part 15 Class A
- IECS-03 Issue 3 Class A
- VCCI (Voluntary Control Council for Interference by Information
Technology Equipment)
|