| Weight |
Weights are approximate.
|
Chassis only
|
22 lb (9.9 kg)
|
Chassis fully configured
|
46 lb (20.7 kg)
|
| Dimensions |
10.5 (H) x 19 (W) x 16 (D) inches; 26.67 x 48.26 x 40.64 cm
|
| Environmental Requirements |
NEBS GR-63-CORE compliant
|
Ambient operating temperature
|
- Long term: 41° to 104° F (5° to 40° C)
- Short term: 23° to 122° F (–5° ˚to
50° ˚C)
|
Ambient operating humidity
|
- Long term: 5% to 85% (noncondensing)
- Short term: 5% to 95% (noncondensing)
|
Ambient storage temperature
|
–40° to 158° F (–40° to +70° C),
95% relative humidity
|
Ambient storage humidity
|
5% to 95% (noncondensing)
|
| Heat Dissipation |
1400 W, 4780 BTU/hour maximum
|
| DC Input |
|
Voltage
|
–40 to –72 VDC
NOTE: If the voltage rises above
–40 VDC, the system powers off. The system does not power on
again until the input voltage reaches –43 +/– 0.5 VDC.
|
Current
|
30 A @ –48 VDC
|
Power
|
1400 W maximum
|
Redundancy (input power)
|
2 independent line feeds
|
| Space Requirements |
- 3 feet (90 cm) behind router or rack
- Do not block air vents on sides of the router.
- Do not place equipment that exhausts hot air to left on
the right of the router.
- Be aware that router exhausts hot air from its left side.
|
| Airflow |
- Airflow direction is in through the right side and out
through the left side. See Figure 53.
|
| NEBS Certification |
- SR-3580 (FD-15): Network Equipment Building System (NEBS)
Criteria Levels, Issue 1, November 1995
- GR-63–CORE: Network Equipment Building System (NEBS)
Requirements: Physical Protection, Issue 2, April 2002
- GR-1089 (LSSGR, FD-15): Electromagnetic Compatibility
and Electrical Safety - Generic Criteria for Network Telecommunications
Equipment, Issue 2, Revision 1, February 1999
|
| Safety Agency Certification |
- AS/NZS 60950:2000 Safety of Information Technology Equipment
- CAN/CSA-C22.2, No. 60950-1–03, First Edition, Information
Technology Equipment - Safety - Part 1: General Requirements
- EN60825-1, Safety of Laser Products - Part 1: Equipment
Class, Requirements, and User's Guide (2001)
- EN60950-1:2001, First Edition, Information Technology
Equipment - Safety - Part 1: General Requirements
- IEC 60950-1(2001-10) Ed. 1.0 Information Technology Equipment
- Safety - Part 1: General Requirements
- Low Voltage Directive (73/23/EEC)
- UL 60950-1, First Edition, Information Technology Equipment
- Safety - Part 1: General Requirements
|
| Electromagnetic Emissions
Agency Certification |
- AS/NZS 3548:1995 (CISPR 22 Class A)
- EMC Directive (89/336/EEC)
- EN55022 Class A (CISPR-22 Class A)
- EN55024, Annex C for WAN Equipment Performance Criteria
A, B, and C
- ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic
Compatibility (EMC) requirements
- FCC Part 15 Class A
- IECS-003 Issue 3 Class A
- VCCI (Voluntary Control Council for Interference by Information
Technology Equipment)
|
| Telecommunications Certification |
- ACA TS 016-1997
- CTR13 – Commission Decision of 9 July 1997 on a
common technical regulation for attachment requirements for terminal
equipment interface for connection to 2048 kbit/s digital structured
ONP leased lines: 97/521/EC – OJ No. L215 Vol. 40, August 1997
- CTR24 – Commission Decision of 9 September 1997
on a common technical regulation for attachment requirements for terminal
equipment interface for connection to 34 Mbit/s digital unstructured
and structured leased lines: 97/639/EC – OJ No. L271 Vol. 40,
3 October 1997
- FCC PART 68
- IECS-003 Issue 3 Class A
- PD7024 – Essential requirements for terminal equipment
intended for connection to unstructured digital leased circuits of
the public telecommunications network using a CCITT recommendation
G,703 interface at a rate of 2048 kbit/s with a 75 ohm unbalanced
presentation, 1994
- RTTE Directive (1999/5/EEC)
|