| Line module label |
COCX-F3 |
| I/O module label |
E3-12 FRAME I/O |
| Number of I/O ports |
|
| Software release |
- First supported: 4.0.2
- Final supported: Not applicable
|
| Description |
- 135 W
- Unchannelized E3 for Frame
|
| Type |
|
| Capability |
|
| Software features |
- See Unchannelized E3 Modules for information about
the layer 2 and layer 3 protocols and applications that this module
combination supports.
|
| Model compatibility |
- ERX7xx models
- ERX14xx models
- ERX310 router
|
| SRP module compatibility |
- SRP-5G+
- SRP-10G
- SRP-40G
- SRP-40G PLUS
- SRP-SE10G
|
| Module redundancy support |
- 1:N redundancy
- NOTE: Line module redundancy
is not supported on the ERX310 router.
|
| Cables and connectors |
- BT43 SMB connector
- Cable that adapts to 75-ohm BNC is available.
- The transmitted signal complies with ITUT G.703, Physical/electrical
characteristics of hierarchical digital interfaces (November 2001)
for cable lengths from 0–137 m (0–450 feet).
- See ERX Hardware Guide, Chapter 5, Cabling
ERX Routers for more information.
|
| LEDs |
|
| Alarms, errors, and events |
- See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 2, Configuring
T3 and E3 Interfaces.
|