| Line module label
|
X.21/V.35
|
| I/O module label
|
X.21/V.35 I/O
|
| Number of I/O ports
|
|
| Software release
|
-
First supported: 2.10.1, 3.3.2
-
Final supported: 7.3.x
|
| Description
|
-
60 W
-
X.21/V.35 synchronous serial interface
|
| Type |
|
| Capability |
|
| Software features
|
-
See ERX Module Guide, Appendix A, Module Protocol Support for
information about the layer 2 and layer 3 protocols and applications that
this module combination supports.
|
| Model compatibility
|
-
ERX-7xx models
-
ERX-1410 router
|
| SRP module compatibility
|
|
| Module redundancy support
|
|
| Cables and connectors
|
-
200-pin proprietary socket on I/O module
-
DB15 X.21 or DB34 V.35 at remote end
-
Serial signals can travel a limited distance without significant
degradation. Slower serial signals can travel farther without degradation
than faster serial signals. See “Cable Lengths” row for the maximum
cable lengths you can use to prevent signal degradation at various transmission
speeds.
|
| Cable Lengths
|
|
Transmission Speed (Hz)
-
2400
-
4800
-
9600
-
19200
-
38400
-
56000
-
2048000
|
Cable Length (Meters/Feet)
-
1250/4100
-
625/2050
-
312/1025
-
156/513
-
78/256
-
31/102
-
8/25
|
| LEDs |
-
See ERX Module Guide, Appendix B, Module LEDs.
|
| Alarms, errors, and events
|
-
See Monitoring Interfaces in the Configuring
X.21/V.35 Interfaces chapter of the JUNOSe Physical Layer
Configuration Guide for Release 8.0.x and earlier.
|