Upgrading a System That Contains Two SRP Modules

In a system that contains two SRP modules, you can upgrade the software without powering off the system.

To upgrade the software in a system that contains two SRP modules:

  1. Connect your antistatic wrist strap to the ESD grounding jack on your router.
  2. Turn off autosynchronization.
    host1#enable
    host1#configure
    Configuring from terminal or file [terminal]?
    Enter configuration commands, one per line. End with CNTL/Z.
    host1 (config)#disable-autosync
    host1 (config)#exit
  3. Halt the redundant SRP module.
    host1#halt standby-srp

    Remove the redundant SRP module from the chassis.
  4. Replace the NVS card on this SRP module.

    Note: The release you are installing must be Release 5.1.2 or higher-numbered 5.x.x release.

  5. Reinsert the SRP module into the chassis.
  6. Force the redundant SRP module to take over from the primary SRP module.
    host1#srp switch
  7. Turn on autosychronization.
    host1#enable
    host1#configure
    Configuring from terminal or file [terminal]?
    Enter configuration commands, one per line. End with CNTL/Z.
    host1 (config)#no disable-autosync
    host1 (config)#exit

    The software is updated on the other SRP module.

After the system is configured with a 5.x.x release, newer releases are supported and can be installed.