Limitations of Automatic Switchover

If automatic switchover is enabled on a slot (the default configuration) and a spare line module is available, issuing some CLI commands for the primary line module causes a switchover (see Table 43).

You can also disable automatic switchover on individual slots. For more information, see Configuring Line Module Redundancy.

Table 43: Commands That Can Cause Automatic Switchover

Command

Reason for Automatic Switchover

slot disable primary-line-module-slot

The command disables the primary line module but not the primary I/O module or IOAs.

reload slot primary-line-module-slot

The command is equivalent to pushing the reset button on the primary line module.