[Contents]
[Prev]
[Next]
[Index]
[Report an Error]
Limitations of Automatic Switchover
If automatic switchover is enabled on a slot (the
default configuration) and a spare line module is available, issuing
some CLI commands for the primary line module causes a switchover
(see Table 43).
You can also disable automatic switchover on individual
slots. For more information, see Configuring Line Module Redundancy.
Table 43: Commands
That Can Cause Automatic Switchover
|
Command
|
Reason for Automatic Switchover
|
|
slot disable primary-line-module-slot
|
The command disables the primary line module but not the primary
I/O module or IOAs.
|
|
reload slot primary-line-module-slot
|
The command is equivalent to pushing the reset button on the
primary line module.
|