Initializing State
After the SRP module transitions into the initializing
state, bulk synchronization of the memory and NVS occurs. This includes
the following:
- File synchronization of the primary NVS with the standby
NVS
- Mirroring of appropriate state and dynamic configuration
information from the active SRP (memory) to the standby SRP (memory)
 |
Note:
Depending on the size of the configuration, this process can
take several minutes.
|
During the initializing state:
- If an unsupported application is configured during initialization,
the system completes initializing and enters the pending state.
- If any other criterion becomes false (or is no longer
met), the system enters the disabled state.
- If a switchover occurs while the system is in this state,
the system cold-restarts.
Once initialization is completed, the system enters
the active state.