[Contents]
[Prev]
[Next]
[Index]
[Report an Error]
Configuring Timing
You can use the timing source command to configure
three timing sources for the system. These sources are known as the
primary, secondary, and tertiary sources. The system periodically
polls the status of the current timing source. If the system discovers
that the current source has become unavailable, it polls the timing
source you specified as next in line. If this source is available,
it switches to this source; if not, it then polls the next source
in line. If the lowest source is unavailable, the system maintains
the SRP clock as the source.
If you enable auto-upgrade, in the event of a source
failure, the system—after switching to a lower source—polls
all higher configured sources and automatically switches back to the
highest timing source when that source becomes available.
The timing select command enables you to specify
which source (primary, secondary, or tertiary) the system is to use
by default. The system will never attempt to upgrade to a source higher
than the selected source.
timing disable-auto-upgrade
- Use to disable the auto-upgrade feature of the system’s
timing selector.
- The system starts out by setting the operational timing
selector to the administratively configured selector. See the timing select command.
- Example
- host1(config)#timing disable-auto-upgrade
- Use the no version to restore
the factory default, which is auto-upgrade enabled.
- See timing disable-auto-upgrade.
timing select
- Use to specify which of the configured timing sources
is used by default.
- Primary timing source is preferred over secondary, and
secondary is preferred over tertiary. See the timing
source command.
- If you enable the auto-upgrade feature, the system does
not try to upgrade beyond the administratively configured selector.
- Example
- host1(config)#timing select secondary
- There is no no version.
- See timing select.
timing source
- Use to specify how the SRP module exchanges timing signals
with an interface.
- You can specify primary, secondary, and tertiary timing
sources.
- You can specify one external source received on an I/O
module or IOA other than the SRP I/O module or SRP IOA.
- You can specify two or more internal sources or external
sources received through the SRP I/O module or SRP IOA external timing
ports.
- On the E120 and E320 routers, you can specify sonet for
only two of the available three timing sources (primary, secondary,
or tertiary).
- The available sources to choose are:
- ds1—DS1 interface
- ds3—DS3 interface
- e1—E1 interface
- e3—E3 interface
- sonet—SONET interface
- internal—Internal system controller (SC) oscillator
- line—External timing input on SRP module
- Example
- host1#timing source secondary sonet 3/0
- There is no no version.
- See timing source.
[Contents]
[Prev]
[Next]
[Index]
[Report an Error]