[Contents] [Prev] [Next] [Index] [Report an Error]

Configuring Channelized OCx/STMx Line Interfaces

The cOCx/STMx modules are generally used for circuit aggregration on the router. These line modules support the following controllers over OC3/STM1 or OC12/STM4, depending on the I/O module used with the line module:

Figure 8 shows the configuration parameters for a sample T1 over DS3 interface configuration.

Figure 8: Parameters for T1 over DS3 Interface Configuration

Image g013674.gif

The following sample command sequence configures T1 over DS3 on a channelized SONET interface as described in Figure 8. See JUNOSe Physical Layer Configuration Guide , for details.

host1(config)#controller sonet 3/0
host1(config-controller)#path 12 oc1 4/1
host1(config-controller)#path 12 ds3 1 channelized
host1(config-controller)#path 12 ds3 1 t1 4
host1(config-controller)#path 12 ds3 1 t1 4/2 timeslots 1, 3-8, 10-12
host1(config)#interface serial 3/0:12/1/4/2

[Contents] [Prev] [Next] [Index] [Report an Error]