Reverting After a Failover
When you specify the auto-revert keyword with the redundant-port command,
the redundant link reverts back to redundant mode when the failed
link becomes active again.
The system uses the following process when you
issue the auto-revert on and auto-revert off keywords:
auto-revert on
- An active link fails and a redundant link becomes active.
- The original active link becomes active.
- The original redundant link fails over to the original
active link.
- The redundant link can fail over to any other active link
again.
auto-revert off
- An active link fails and a redundant link becomes active.
- The original active link becomes active.
- The original redundant link remains the active link.
- You can force the link to fail over by issuing the redundant-port force-failover command.