mdl string
Syntax
mdl string { eic eicValue | fic ficValue | lic licValue | unit unitValue | pfi pfiCode |
port portValue | generator genValue }
no mdl string { eic | fic | lic | unit | pfi | port | generator
}
Release Information
Command introduced before JUNOSe Release
7.1.0.
Description
Allows you to specify an MDL message on a T3 interface
as defined in the ANSI T1.107a-1990 specification. The no version restores the default value to the specified
MDL message or to all MDL messages.
Options
-
eicValue—Equipment identification
code; 1–10 characters; default value is the null value.
-
ficValue—Frame identification
code; 1–10 characters; default value is the null value.
-
licValue—Line identification
code; 1–11 characters; default value is the null value.
-
unitValue—Unit identification
code; 1–6 characters; default value is the null value.
-
pfiCode—Facility identification
code to send in the MDL path message; 1–38 characters; default
value is the null value.
-
portValue—Equipment port number
to send in the MDL idle signal message; 1–38 characters; default
value is the null value.
-
genValue—Generator number
to send in the MDL test signal message; 1–38 characters; default
value is the null value.
Controller Configuration