You can use the output filtering feature of the show command to include or exclude lines of output based on a text string you specify. See Command Line Interface in JUNOSe System Basics Configuration Guide.
baseline interface
- host1#baseline interface serial 2/0
show controllers e3
show controllers t3
![]() |
Note: The alarms detected field does not appear for interfaces that you disabled in the software. |
host1#show controllers t3 2/0
DS3 2/0 Description: boston09 hdlc channel ifAdminStatus = ifAdminDown snmp trap link-status = enabled No alarms detected Framing is C-BIT, Line Code is B3ZS, Clock Source is Line Cable Length is 0 ft Loopback Disabled DSU Mode is Larscom DSU Bandwidth is 4000 DSU Scrambler is off MDL Transmit Path is not active MDL Transmit Test-Signal is active MDL Transmit Idle-Signal is not active Equipment Identification Code is ERX-1400 Line Identification Code is Bldg 10 Frame Identification Code is null string Unit Identification Code is 080001 Facility Identification Code is Site 25 Port Code is Port 0800 Generator Number is null string
Number of valid interval - 96 Time elapse in current interval - 861
Ds3 Current Interval Counters P-bit errored seconds = 0 P-bit severely errored seconds = 0 Severely errored frame seconds = 0 Unavailable seconds = 0 Line code violations = 0 P-bit coding violations = 0 Line errored seconds = 0 C-bit coding violations = 0 C-bit errored seconds = 0 C-bit severely errored seconds = 0
Ds3 Last Interval Counters P-bit errored seconds = 0 P-bit severely errored seconds = 0 Severely errored frame seconds = 0 Unavailable seconds = 0 Line code violations = 0 P-bit coding violations = 0 Line errored seconds = 0 C-bit coding violations = 0 C-bit errored seconds = 0 C-bit severely errored seconds = 0 Ds3 24 Hour Total Counters P-bit errored seconds = 0 P-bit severely errored seconds = 0 Severely errored frame seconds = 0 Unavailable seconds = 0 Line code violations = 0 P-bit coding violations = 0 Line errored seconds = 0 C-bit coding violations = 0 C-bit errored seconds = 0 C-bit severely errored seconds = 0
host1#show controllers t3 brief
Interfaces ifAdminStatus OperationalStatus 5/0(channelized) up up 5/1(channelized) up up 5/2(channelized) up down 5/3(channelized) down down 5/4(channelized) down down 5/5(channelized) down down 5/6(channelized) down down 5/7(channelized) down down 5/8(channelized) down down 5/9(channelized) down down 5/10(channelized) down down 5/11(channelized) down down 3/0(channelized) down down 3/1(channelized) down down 3/2(channelized) down down 4/0:1/1(unchannelized) up down 4/2:1/1(channelized) up lowerLayerDown
show controllers t3 remote
host1#show controllers t3 5/0 remote
Far End MDL Carrier bit is not set Far End Equipment Identification Code is the null string Far End Line Identification Code is the null string Far End Frame Identification Code is the null string Far End Unit Identification Code is the null string Far End Facility Identification Code is the null string Far End Generator Number is the null string Far End Port Number is the null string
Number of valid interval - 3 Time elapse in current interval - 756
Ds3 Current Interval Counters C-bit errored seconds = 0 C-bit severely errored seconds = 0 C-bit coding violations = 0 Unavailable seconds = 0 Invalid seconds = 0
Ds3 Last Interval Counters C-bit errored seconds = 0 C-bit severely errored seconds = 0 C-bit coding violations = 0 Unavailable seconds = 0 Invalid seconds = 0
Ds3 24 Hour Total Counters C-bit errored seconds = 1 C-bit severely errored seconds = 1 C-bit coding violations = 330 Unavailable seconds = 0 Invalid seconds = 0