[Contents]
[Prev]
[Next]
[Index]
[Report an Error]
Configuring a T3 or an E3 Controller
To configure a T3 or an E3 controller:
- Select the T3 or E3 controller from Global Configuration
mode.
- host1(config)#controller t3 3/2
- Enable the T3 or E3 controller.
- host1(config-controll)#no shutdown
- (CT3/T3-F0 line module only) Enable unchannelized operation
for this controller.
- host1(config-controll)#no channelized
channelized
- Use to enable channelized T3 operation on an interface
of a CT3/T3-F0 line module.
- Example
- host1(config-controll)#channelized
- Use the no version to enable
unchannelized T3 operation on an interface for a CT3/T3-F0 line module.
- See channelized.
controller e3
- Use to specify an E3 controller in slot/port format.
-
slot—Number of the slot in
which the line module resides in the chassis
-
port—Number of the port on
the I/O module
- Example
- host1(config)#controller e3 3/2
- There is no no version.
- See controller e3.
controller t3
- Use to specify a T3 controller in slot/port format.
-
slot—Number of the slot in
which the line module resides in the chassis
-
port—Number of the port on
the I/O module
- Example
- host1(config)#controller t3 0/1
- There is no no version.
- See controller t3.
shutdown
- Use to disable a T3 or an E3 controller.
- The T3 or E3 interface is disabled by default.
- Example
- host1(config-controll)#shutdown
- Use the no version to restart
a disabled interface.
- See shutdown.