CTP150 Interface Module HD-26 Connector Cable Pinouts

 

The CTP150 device has five separate EIA-530 cabling options for the serial interface module, with a male HD-26 connector on the module end and the following connectors on the DCE or DTE end:

  • Female DB-25 connector on the DCE end for EIA-530/RS-422/V.11, RS-232/V.24, V.35

  • Male DB-25 connector on the DTE end for EIA-530/RS-422/V.11, RS-232/V.24, V.35

  • Female DB-15 connector on the DCE end for X.21

  • Male DB-15 connector on the DTE end for X.21

  • RJ-45 connector for Radio V.24 Sync interface

The pinouts for these connections have different configurations for EIA-530, RS-232, voice, and T1 interface signals.

EIA-530 Connector Interface Signal Pinouts (DB-25 Female DCE)

Table 1 lists the EIA-530 interface signal pinouts for the HD-26 connector to the female DB-25 connector for the CTP150 platform.

Table 1: EIA-530 DCE Connector Interface Signals for HD-26 to Female DB-25

HD-26 Pin

DB-25 Pin

Description

Circuit

1

3

Receive Data—A (output from CTP)

BB

2

17

Receive Clock—A (output from CTP)

DD

3

15

Transmit Clock (from DCE)—A (output from CTP)

DB

4

24

Transmit Clock (from DTE)—A (input to CTP)

DA

5

2

Transmit Data (SD)—A (input to CTP)

BA

6

8

Data carrier detect (DCD)—A (output from CTP)

CF

7

6

Data set ready (DSR)—A (output from CTP)

CC

8

5

Clear to send (CTS)—A (output from CTP)

CB

9

13

Clear to send (CTS)—B (output from CTP)

CB

10

19

Request to send (RTS)—B (input to CTP)

CA

11

4

Request to send (RTS)—A (input to CTP)

CA

12

20

Data terminal ready (DTR)—A (input to CTP)

CD

13

18

Local loopback (LL) (input to CTP)

LL

14

16

Receive Data (RD)—B (output from CTP)

BB

15

9

Receive Clock—B (output from CTP)

DD

16

12

Transmit Clock (from DCE)—B (output from CTP)

DB

17

11

Transmit Clock (from DTE)—B (input to CTP)

DA

18

14

Transmit Data—B (input to CTP)

BA

19

10

Data carrier detect (DCD)—B (output from CTP)

CF

20

22

Data set ready (DSR)—B (output from CTP)

CC

21

21

Remote loopback (RL) (input to CTP)

RL

22

25

Test mode (TM) (output from CTP)

TM

24, 26

7

Signal ground (GND)

Ground

25

23

Data terminal ready (DTR)—B (input to CTP)

CD

EIA-530 Connector Interface Signal Pinouts (DB-25 Male DTE)

Table 2 lists the EIA-530 interface signal pinouts for the HD-26 connector to the male DB-25 connector for the CTP150 platform.

Table 2: EIA-530 DTE Connector Interface Signals for HD-26 to Male DB-25

HD-26 Pin

DB-25 Pin

Description

1

2

Transmit Data—A (output from CTP)

2

24

Transmit Clock (from DTE)—A (output from CTP)

3

15

Transmit Clock (from DCE)—A (input to CTP)

4

17

Receive Clock—A (input to CTP)

5

3

Receive Data—A (input to CTP)

6

8

Data carrier detect—A (input to CTP)

7

20

Data terminal ready—A (output from CTP)

8

4

Request to send—A (output from CTP)

9

19

Request to send—B (output from CTP)

10

13

Clear to send—B (input to CTP)

11

5

Clear to send—A (input to CTP)

12

6

Data set ready—A (input to CTP)

13

18

Local loopback (output from CTP)

14

14

Transmit Data—B (output from CTP)

15

11

Transmit Clock (from DTE)—B (output from CTP)

16

12

Transmit Clock (from DCE)—B (input to CTP)

17

9

Receive Clock—B (input to CTP)

18

16

Receive Data—B (input to CTP)

19

10

Data carrier detect—B (input to CTP)

20

23

Data terminal ready—B (output from CTP)

21

25

Test mode (input to CTP)

22

21

Remote loop (output from CTP)

24, 26

7

Ground

25

22

Data set ready—B (input to CTP)

X.21 Connector Interface Signal Pinouts (DB-15 Female DCE)

Table 3 lists the X.21 interface signal pinouts for the HD-26 connector to the female DB-15 connector for the CTP150 platform.

Table 3: X.21 DCE Connector Interface Signals for HD-26 to Female DB-15

HD-26 Pin

DB-15 Pin

Description

1

4

Receive Data—A (output from CTP)

2

6

Receive Clock—A (output from CTP)

4

7

Transmit Clock—A (input to CTP)

5

2

Transmit Data—A (input to CTP)

8

5

Signal Out—A (output from CTP)

9

12

Signal Out—B (output from CTP)

10

10

Signal In—B (input to CTP)

11

3

Signal In—A (input to CTP)

14

11

Receive Data—B (output from CTP)

15

13

Receive Clock—B (output from CTP)

17

14

Transmit Clock—B (input to CTP)

18

9

Transmit Data—B (input to CTP)

24, 26

8

Ground

X.21 Connector Interface Signal Pinouts (DB-15 Male DTE)

Table 4 lists the X.21 interface signal pinouts for the HD-26 connector to the male DB-15 connector for the CTP150 platform.

Table 4: X.21 DTE Connector Interface Signals for HD-26 to Male DB-15

HD-26 Pin

DB-15 Pin

Description

1

4

Transmit Data—A (output from CTP)

2

6

Transmit Clock—A (output from CTP)

4

7

Receive Clock—A (input to CTP)

5

2

Receive Data—A (input to CTP)

8

5

Signal Out—A (output from CTP)

9

12

Signal Out—B (output from CTP)

10

10

Signal In—B (input to CTP)

11

3

Signal In A (input to CTP)

14

11

Transmit Data—B (output from CTP)

15

13

Transmit Clock—B (output from CTP)

17

14

Receive Clock—B (input to CTP)

18

9

Receive Data-–B (input to CTP)

24, 26

8

Ground

V.24 Connector Interface Signal Pinouts (RJ-45 Male)

Table 5 lists the V.24 interface signal pinouts for the HD-26 connector to the male RJ-45 connector for the CTP150 platform.

Table 5: V.24 Connector Interface Signals for HD-26 to RJ-45

HD-26 Pin

RJ-45 Pin

Description

1

5

TX

2

1

RCLK

3

3

TCLK

5

6

RX

6

2

CD

8

7

CTS

11

8

RTS

24, 26

4

GND

T1/E1 Interface Signal Pinouts (RJ-45 Male)

Table 6 lists the T1/E1 interface module pinout for the RJ-45 connector.

Table 6: T1/E1 Interface Module—RJ-45 Connector Pinout

RJ-45 Pin

Signal

1

RX Ring

2

RX Tip

3

4

TX Ring

5

TX Tip

6

7

8