The AWS device activation process takes up to 30 minutes. If the process does not complete in 30 minutes, a timeout might occur and you must retry the process. You do not need to download the cloud formation template again.
To retry the process:
For an AWS spoke, during the activation process, the device status on the Activate Device page is displayed as Detected even though the device is down.
Workaround: None.
Bug Tracking Number: CXU-19779.
In a CSO HA environment, two RabbitMQ nodes are clustered together, but the third RabbitMQ node does not join the cluster. This might occur just after the initial installation, if a virtual machine reboots, or if a virtual machine is powered off and then powered on.
Workaround: Do the following:
rabbitmqctl stop_app
service rabbitmq-server stop
rabbitmqctl stop_app command
rm -rf /var/lib/rabbitmq/mnesia/
service rabbitmq-server start
rabbitmqctl start_app
Bug Tracking Number: CXU-12107
CSO may not come up after a power failure.
Workaround:
/root/Contrail_Service_Orchestration_3.3/
directory../python.sh recovery/components/reinitialize_pods.py
If there is an error in connecting (port 22: Connection refused), then you must recover the VRR by following step 5 through 19.
Note: Do not execute the virsh undefine vr commandr because doing so will cause the VRR configuration to be lost and the configuration cannot be recovered.
/root/ubuntu_vm/vrr/vrr-15.1R6.7.qcow2
directory./root/disks/vrr-15.1R6.7.qcow2
directory to the /root/ubuntu_vm/vrr/vrr-15.1R6.7.qcow2
directory.If the VRR is not running, check that the image that was copied was the uncorrupted image and re-try the steps from step 7.
The following is the base configuration (JSON format) for the VRR. (In the configuration below, <vrr-ip-address> is the IP address of the VRR and <vrr-password> is the password that was configured for the VRR.
{ "input": { "job_name_prefix": "ImportPop", "pop": [{ "dc_name": "regional", "device": [{ "name": "vrr-<vrr-ip-address>", "family": "VRR", "device_ip": "<vrr-ip-address>", "assigned_device_profile": "VRR_Advanced_SDWAN_option_1", "authentication": { "password_based": { "username": "root", "password": "<vrr-password>" } }, "management_state": "managed", "pnf_package": "null" }], "name": "regional" }] }}
Bug Tracking Number: CXU-16530
In a HA setup, after the central or regional microservices server goes down, policy deployments are stuck in the In Progress state.
Workaround: Contact Juniper Networks Technical Support.
Bug Tracking Number: CXU-20099.
In a HA setup, when a failed infrastructure VM recovers, it might not join the ArangoDB cluster.
Workaround:
Bug Tracking Number: CXU-20430.
In some cases, when the power fails, the ArangoDB cluster does not form.
Workaround: Use the workaround specified for CXU-20340.
Bug Tracking Number: CXU-20346.
In a HA setup, the time configured for the CAN VMs might not be synchronized with the time configured for the other VMs in the setup. This can cause issues in the throughput graphs.
Workaround:
/etc/ntp.conf
file to point to the desired NTP server.After the NTP process restarts successfully, can-vm2 and can-vm3 automatically resynchronize their times with can-vm1.
Bug Tracking Number: CXU-15681
In CSO Release 3.3, the LTE link can be only a backup link. Therefore, the SLA metrics are not applicable and default values of zero might be displayed on the Application SLA Performance page, which can be ignored.
Workaround: None.
Bug Tracking Number: CXU-19943
In a dual CPE spoke, non-cacheable applications do not work when the initial path is on CPE0 and the APBR path selected is on CPE1.
Workaround: None.
Bug Tracking Number: PR1340331
In an SRX Series dual CPE site, when the application traffic takes the Z-mode path, the application throughput reported in the Administration Portal GUI is lower than the actual data throughput.
Workaround: None.
Bug Tracking Number: PR1347723.
If all the active links, including OAM connectivity to CSO, are down and the LTE link is used for traffic, and if the DHCP addresses change to a new subnet, the traffic is dropped because CSO is unable to reconfigure the device.
Workaround: None.
Bug Tracking Number: CXU-19080.
On the Site SLA Performance page, applications with different SLA scores are plotted at the same coordinate on the x-axis.
Workaround: None.
Bug Tracking Number: CXU-19768.
When all local breakout links are down, site to Internet traffic fails even though there is an active overlay to the hub.
Workaround: None.
Bug Tracking Number: CXU-19807
When the CPE device is not able to reach CSO, DHCP address changes on WAN interfaces might not be detected and reconfigured.
Workaround: None.
Bug Tracking Number: CXU-19856
When the OAM link is down, the communication between the CPE devices and CSO does not work even though CSO can be reached over other WAN links. There is no impact to the traffic.
Workaround: None.
Bug Tracking Number: CXU-19881.
In a full mesh topology, the GRE IPsec down alarms are not created for some overlays during link failures.
Workaround: None.
Bug Tracking Number: CXU-20403.
If you specify an MPLS link without local breakout capability as the backup link, then Internet breakout traffic is dropped because the overlay link to hub will not be used for Internet traffic if local breakout is enabled for the site.
Workaround: Configure an Internet or an LTE link as the backup link.
Bug Tracking Number: CXU-20447.
If you define an SLA profile for a static SD-WAN policy but do not remove the default values for the SLA parameters and deploy the policy, the policy is deployed as a dyanmic SD-WAN policy.
Workaround: When you define the SLA profile for static SD-WAN policy, ensure that you remove the default values for the SLA parameters.
Bug Tracking Number: CXU-20499.
When you modify the path preference of an existing SLA profile that has already been deployed and redeploy the SD-WAN policy, the path of the SLA profile is not updated on the CPE device.
Workaround: Modify the path preference in an SLA profile that is not yet deployed.
Bug Tracking Number: CXU-20540.
For non-cacheable applications, in a hub and spoke topology, on link switchover, in some cases, the traffic between the hub and spoke might take incorrect physical path because the existing session flow is not updated. However, there is no traffic loss.
Workaround: None.
Bug Tracking Number: PR1341274
In the bandwidth-optimized SD-WAN mode, when the same SLA is used in the SD-WAN policy for different departments and an SLA violation occurs, two link switch events that appear identical, because the department name is missing from the event details, are displayed.
Workaround: None.
Bug Tracking Number: CXU-20529.
When you configure a high delay and loss on the OAM link, the link switch might be delayed or might not occur.
Workaround: None.
Bug Tracking Number: CXU-20562.
For a tenant with bandwidth-optimized SD-WAN mode, the SLA performance for the site is always displayed as 0/100.
Workaround: None.
Bug Tracking Number: CXU-20563.
If you create a firewall policy with a large number of firewall policy intents and deploy the policy on a tenant with a higher sites with LAN segments and monitoring enabled, the policy deployment fails.
Workaround: None.
Bug Tracking Number: CXU-20292
When you create a NAT pool, specify the Translation as Port/Range, configure the port as a range, and enter an incorrect starting port number, you cannot enter the ending port number and the NAT pool is created with a single port value instead of a range.
Workaround: When you create a NAT pool with a port range, ensure that the starting port number is between 1,024 through 65,335 and then enter the corresponding ending port number between 1,024 through 65,335.
Bug Tracking Number: CXU-20366.
On the Active Database page in Customer Portal, the wrong installed device count is displayed. The count displayed is for all tenants and not for a specific tenant.
Workaround: None.
Bug Tracking Number: CXU-20531.
The tenant delete operation fails when CSO is installed with an external Keystone.
Workaround: You must manually delete the tenant from the Contrail OpenStack user interface.
Bug Tracking Number: CXU-9070
When both the OAM and data interfaces are untagged, ZTP fails when using a NFX Series platform as CPE.
Workaround: Use tagged interfaces for both OAM and data.
Bug Tracking Number: CXU-15084
The tenant creation job may fail if connectivity from CSO to VRR is lost during job execution.
Workaround: If the tenant creation job fails and the tenant is created in CSO, delete the tenant and retrigger the tenant creation.
Bug Tracking Number: CXU-16884
If the tenant name exceeds 16 characters, the activation of the SRX hub device fails.
Workaround: Delete the tenant and re-create a new tenant with name less than 16 characters or less and retry the activation.
Bug Tracking Number: PR1344369.
For tenants with a large number of spoke sites, the tenant deletion job fails because of token expiry.
Workaround: Retry the tenant delete operation.
Bug Tracking Number: CXU-19990.
In some cases, on the Monitor Overview page (Monitoring > Overview) for a site, the ZTP status is displayed incorrectly when you hover over the site.
Workaround: None.
Bug Tracking Number: CXU-20226.
In some cases, if automatic license installation is enabled in the device profile, after ZTP is complete, the license might not be installed on the CPE device even though license key is configured successfully.
Workaround: Reinstall the license on the CPE device by using the Licenses page on the Administration Portal.
Bug Tracking Number: PR1350302.
In the scenario where the redirect service from
Juniper (redirect.juniper.net) is not being used, after you upgrade
an NFX device to Junos OS Release 15.1X53-D472, the device is unable
to connect to the regional server because the phone home server certificate
(phd-ca.crt
) is reverted to the factory
default.
Workaround: Manually copy the regional certificate to the NFX device.
Bug Tracking Number: PR1350492.
In a hub and spoke topology with multi-tenancy (network segmentation) enabled, the reverse traffic from the hub to the originating spoke might not take the same path as the traffic in the forward direction. There is no traffic loss.
Workaround: None.
Bug Tracking Number: CXU-20494.
In the Configure Site workflow for a full mesh topology with multitenancy enabled, the option to connect the CPEs only to the hub is not supported; that is, if you specify false for the used_for_meshing parameter, this option is ignored.
Workaround: None.
Bug Tracking Number: CXU-20495.
For hybrid WAN tenants, during site creation, all the VIMs in the system are displayed even though a specific VIM is already assigned during the tenant creation.
Workaround: None.
Bug Tracking Number: CXU-20371.
When you use DHCP for the activation of a dual CPE device, ZTP might fail because the device takes longer than expected to to connect to the Device Connectivity Service (DCS).
Workaround: Retry the failed ZTP job.
Bug Tracking Number: CXU-20467.
During site addition, if you create a department but do not assign a LAN segment to that department, during the site activation, the firewall policy deployment fails.
Workaround: Do one of the following:
Go to the Site-Name page, and on the LAN tab, add a new LAN segment to the department that did not have any LAN segments assigned during site creation.
Alternatively, during site addition, when you create a department, ensure that you assign at least one LAN segment to that department.
Bug Tracking Number: CXU-20502.
When the primary and backup interfaces of the CPE device uses the same WAN interface of the hub, the backup underlay might be used for Internet or site-to-site traffic even though the primary links are available.
Workaround: Ensure that you connect the WAN links of each CPE device to unique WAN links of the hub.
Bug Tracking Number: CXU-20564.
When a spoke is recalled, the configuration remains on the hub. When the spoke is reprovisioned, the activation fails and an error message indicating that the source and destination addresses of the tunnel cannot be the same is displayed in the logs.
Workaround: Clean up the configuration of the recalled spoke in the hub and reprovision the spoke with a new name.
Bug Tracking Number: CXU-20441.
When you bring down or bring up an AWS availability zone, there might be a momentary slowdown in the response time of the Administration Portal GUI and some in-progress jobs might be affected.
Workaround: Wait for five minutes and retry the failed jobs.
Bug Tracking Number: CXU-20463.
If you create VNF instances in the Contrail cloud by using Heat Version 2.0 APIs, a timeout error occurs after 120 instances are created.
Workaround: Contact Juniper Networks Technical Support.
Bug Tracking Number: CXU-15033
When you upgrade the gateway router (GWR) by using the CSO GUI, after the upgrade completes and the gateway router reboots, the gateway router configuration reverts to the base configuration and loses the IPsec configuration added during Zero Touch Provisioning (ZTP).
Workaround: Before you upgrade the gateway router by using the CSO GUI, ensure that you do the following:
Bug Tracking Number: CXU-11823.
If you run the script to revert the upgraded setup to CSO Release 3.2.1, in some cases, the status of the ArangoDB cluster becomes unhealthy.
Workaround:
If the command executes successfully, proceed to 3
If there is no progress after 30 seconds:
If the command executes successfully, proceed to step 5
If there is no progress after 30 seconds:
If the command executes successfully, proceed to step 7
If there is no progress after 30 seconds:
The following is a sample output.
tcp6 0 0 :::8528 :::* LISTEN 0 54213 9220/arangodb tcp6 0 0 :::8529 :::* LISTEN 0 44018 9327/arangod tcp6 0 0 :::8530 :::* LISTEN 0 91216 9289/arangod tcp6 0 0 :::8531 :::* LISTEN 0 42530 9232/arangod
Bug Tracking Number: CXU-20397.
On a CPE configured with an LTE backup link, LTE link flaps are observed when the CPE is running for a longer period.
Workaround: None.
Bug Tracking Number: PR1349613.
In a HA setup, when you upgrade from JCS 3.2.1 to JCS 3.3, the Kubernetes system pods for the central or regional load balancer VM are in the Terminating state. This causes the load balancer VM to be in the Not Ready state, which causes the health check to fail during the upgrade.
Workaround:
If the central load balancer VM is in the Not Ready state, execute the following command: salt 'csp-central-lbvm*' cmd.run 'reboot'.
If the regional load balancer VM is in the Not Ready state, execute the following command: salt 'csp-regional-lbvm*' cmd.run 'reboot'
upgrade.sh
script
to continue with the upgrade.Bug Tracking Number: CXU-20271.
The provisioning of CPE devices fail if all VRRs within a redundancy group are unavailable.
Workaround: Recover the VRR that is down and retry the provisioning (ZTP) job.
Bug Tracking Number: CXU-19063
In the centralized deployment, after you import a POP, the CPU, memory, and storage allocation are displayed as zero.
Workaround: Refresh the UI and the correct information is displayed.
Bug Tracking Number: CXU-19105
The CSO health check displays the following error message: ERROR: ONE OR MORE KUBE-SYSTEM PODS ARE NOT RUNNING
Workaround:
Bug Tracking Number: CXU-20275.
In a department, when there are two LAN segments with DHCP enabled, only one DHCP server setting is deployed on the device.
Workaround: Enable DHCP only for one LAN segment in a department.
Bug Tracking Number: CXU-20519.
For LAN segments that contain overlapping IP addresses:
If you create two or more LAN segments that contain overlapping IP addresses and either select one of the LAN segments with overlapping IP addresses or do not select any of the LAN segments with overlapping IP addresses and click Deploy, the deployment for all LAN segments that are not in the VPN attached state is triggered.
Workaround: To create two or more LAN segments with overlapping IP addresses, create and trigger the deploy operation for one LAN segment at a time. After the deployment is successful, create and trigger the deploy operation for the next LAN segment with the overlapping IP address, and so on.
If you delete two or more LAN segments that contain overlapping IP addresses, select the deleted LAN segments and then trigger the deploy operation, an incorrect error message indicating that the IP prefixes are the same is displayed.
Workaround: To delete and deploy two or more LAN segments with overlapping IP addresses, delete the LAN segments and then trigger the deploy operation without selecting any LAN segments.
Bug Tracking Number: CXU-20365.
The Grant RMA operation fails for a multihome hub device.
Workaround: None.
Bug Tracking Number: CXU-20457.
After the upgrade, the health check on the standalone Contrail Analytics Node (CAN) fails.
Workaround:
Bug Tracking Number: CXU-20470.
When the LTE modem is disconnected or disabled in the NFX250 CPE device, an alarm is triggered. However, the underlay link status in Sites page might not display the alarm.
Workaround: None.
Bug Tracking Number: CXU-20492.