Network Director Release Notes, Release 1.5

Overview

Junos Space Network Director enables unified management of Juniper Networks EX Series Ethernet Switches, EX Series Ethernet switches with ELS support, QFX Series switches, QFabric, wireless LAN devices, and VMware vCenter devices in your network. It provides full network life cycle management by simplifying the discovery, configuration, visualization, monitoring, and administration of large networks containing physical and virtual devices. The software images for Network Director, Network Director API, Junos Space Management Platform, additional scripts, Network Director API Reference documentation, and the release notes for Network Director Release 1.5 are available at: Junos Space and Junos Space Network Director Download page.

New Features for Network Director in Release 1.5

Network Director Release 1.5 introduces the following features:

For information about these features, see the product documentation that is available from the Network Director user interface or see https://www.juniper.net/techpubs/.

Junos Space Network Management Platform Requirements

Network Director Release 1.5 is supported on Junos Space Network Management Platform Release 13.1P5. Network Director Release 1.5 is also supported on Junos Space Network Management Platform Release 13.1P1. However, with Junos Space Network Management Platform Release 13.1P1, you may not be able to perform the complete search functionality in Network Director.

Network Director API Release 1.5 is supported only on Junos Space Network Management Platform Release 13.1P5.

Network Director is supported on a Junos Space JA1500 Appliance or a Junos Space Virtual Appliance that meets the hardware requirements specified in the Junos Space documentation. It is not supported on a Junos Space instance running on a Juniper Networks NSM3000 appliance.

Supported Platforms for Network Director in Release 1.5

Table 1 lists the supported platforms and the corresponding qualified Junos OS releases, Mobility System Software (MSS) releases, or VMware releases:

Table 1: Supported Platforms and the Software Versions for Network Director

Supported Platforms

Qualified Junos OS, MSS, or the ESXi Releases

EX Series Switches:

EX2200 and EX2200-C (standalone and Virtual Chassis) and
EX3200
EX3300 (standalone and Virtual Chassis)
EX4200 (standalone and Virtual Chassis)
EX4500 (standalone and Virtual Chassis)
EX4550 (standalone and Virtual Chassis)
Mixed EX4200, EX4500, and EX4550 Virtual Chassis
EX6200
EX8200 (standalone and Virtual Chassis)

Junos OS Releases 12.1, 12.2, 12.3, and 13.2X50-D10.2

EX Series Switches with ELS:

EX4300 (standalone and Virtual Chassis)
EX9200

Junos OS Release 13.2X50-D10.2 for EX4300

Junos OS Release 13.2R1 for EX9200

Note: The access profile configuration and the port security configuration that are part of the Port profile configuration might not work on EX9200 switches that run Junos OS Release 12.3R2.5.

WLC Series wireless LAN controllers:

WLC2


WLC8
WLC800
WLC880
WLC2800
WLC200


MSS Releases 7.7 and 8.0 for WLC2

MSS Releases 7.7, 8.0, and 9.0 for other controllers

JunosV wireless LAN controller
WLC100

MSS Release 9.0

WLA Series wireless LAN access points:

WLA321
WLA322
WLA422
WLA432
WLA522
WLA532
WLA620
WLA622
WLA632

MSS Releases 7.7, 8.0, and 9.0

Data center switches:

QFX3500
QFX3600
QFabric systems (QFX3000-G and QFX3000-M)

Junos OS Releases 12.3X50-D30.2 or 12.3X50-D35 for QFX3500 and QFX3600

Junos OS Release 13.1X50-D15 for QFabric systems

Note: Junos OS Release 13.1X50-D15 and Release 12.3X50-D35 will release soon after Network Director 1.5.

VMware vCenter server
VMware host

VMware ESX versions 4.0 and 4.1

VMware ESXi versions 5.0 and 5.1

Installation Instructions for Network Director Application and Network Director API, Release 1.5

Before you begin to install Network Director Release 1.5, ensure that the Network Management Platform is at the required release with the latest patch release installed. See Junos Space Network Management Platform Requirements for requirements information.

Note: If you have installed Network Director Release 1.5 Beta on the same Junos Space appliance, then you must uninstall it before installing Network Director Release 1.5.

Note: If you have Junos Space Virtual Control installed on your Junos Space Network Management Platform, you must uninstall it and run the clean up script before you install Network Director. You can download the cleanup script for Virtual Control from the Junos Space and Junos Space Network Director Download page.

The software image for Network Director Release 1.5 enables you to install Network Director and Network Director API together.

A prescribed order is always required for installation or upgrade of Network Director and Network Director API. Use the following table to determine the prescribed order of tasks for your installation or upgrade:

Type of Upgrade or Installation

Order of Installation Required

New Installation—Network Director and Network Director API

  1. Install or upgrade to a supported release of Network Management Platform. See Junos Space Network Management Platform Requirements for requirements information.
  2. Install Network Director, Release 1.5.

    Once the installation is complete, the system lists Network Director and Network Director API in the installed applications list.

  3. Only for Network Director API, import the network topology and the static configurations.

Upgrade from Release 1.0 or 1.1—Network Director, Release 1.5

  1. Upgrade to a supported release of Network Management Platform. See Junos Space Network Management Platform Requirements for requirements information.
  2. Install Network Director, Release 1.5.

For detailed instructions about installing Network Director and Network Director API, see Network Director Quick Start Guide.

Junos Space DMI Schema Requirements for Network Director

In most installations, Junos Space automatically matches DMI schemas to device families. But there might be certain situations where your network uses a device for which Junos Space does not have the latest or supported schema available. In such instances, you must obtain and upload the requisite schema and set it as the default DMI schema for each device family. Set a default DMI schema for each device family to enable Junos Space to apply an appropriate schema to a device family.

Table 2 lists the latest DMI schema that you must obtain and upload in Junos Space before you start working on Network Director Release 1.5:

Table 2: DMI Schemas

Device

Name of the DMI Schema

Device Family

EX4300
EX9200

JUNOS 13.2X50-D10.2

junos-ex

MX Series (applies to Network Director API only)

JUNOS 12.3R4.6

junos

QFabric devices

JUNOS 13.1X50-D15

junos-qf

QFX3500
QFX3600

JUNOS 12.3X50-D30.2

junos-qfx

SRX Series (applies to Network Director API only)

JUNOS 12.1R7.9

junos-es

For detailed steps on acquiring and uploading the schema files, see the Junos Space Documentation or Managing DMI Schemas Overview.

Installation and Upgrade Scripts

You must run these scripts, if your Junos Space or Network Director setup is for the scenario described against each script:

The README file for these scripts provide detailed steps about how to use these scripts.

Operational Notes on General Interface Use

Operational Notes on Device Discovery and Management

Known Issues in Network Director Release 1.5

The following are known issues in Network Director Release 1.5.

PR Number

Problem Description

Installation and Upgrade Issues

881653

The system does not prevent the installation of Network Director Release 1.5 on Junos Space even if Junos Space already has Virtual Control installed. Virtual Control and Network Director cannot be coexist on the same Junos Space appliance.

Workaround: Ensure that Virtual Control is uninstalled cleanly from Junos Space before you install Network Director. For detailed steps, see Network Director Quick Deployment Guide.

General User Interface and Preferences Issues

911626

Not able to search with partial characters based on the name column everywhere.

Workaround: Use a wildcard (*) to perform the search.

General Build Mode and Deploy Mode Issues

957213

If the host name of Nodes or Interconnects that belong to different QFabric systems are identical, Network Director displays the links in the QFabric topology only for the QFabric system that was discovered first. Links for the subsequent QFabric systems are not displayed.

Workaround: You must change the hostnames of Nodes or Interconnects to ensure that the hostnames are unique. After you do this, rediscover or resynchronize the QFabric system from Network Director.

960716

Alarms generated on QFX devices are not displayed in the Topology view.

Workaround: Use the Fault mode to view alarms for QFX devices.

962676

Search by "MAC Address" and "Discovered Through" fields does not work in the Manage Network Adapter Associations page.

Workaround: None available at present.

963883

Virtual Topology view displays incorrect details if there are physical NICs on hosts that are connected to multiple TORs on a QFabric system.

Workaround: None available at present.

945107

While deploying a Port profile of type Switched Uplink on QFX devices, Network Director does not deploy the classifier associations to the interface. As a result, after deployment if you re-synchronize the device from Network Director, duplicate CoS profiles and Port profiles are created in Network Director.

Workaround: Clone the default COS profile named "juniper_DC_Hier_Ethernet_CoS". Attach the cloned profile to the Switched Uplink Port profile and deploy the profile to the QFX devices.

946576

If an access point’s serial number contains Capital letters, Network Director creates duplicate access points in the Inventory and Tree view.

Workaround: None available at present.

947690

Network Director does not promote a port profile if the trunk port is having vlan "all" as membership.

Workaround: None available at present.

963603

Network Director does not support configuring WLA with model WLA532E-WW for the country code RU (Russia).

Workaround: You can configure WLA with model WLA532E-WW for the country code RU (Russia) using the CLI or RingMaster.

936543

Automatic profile creation (as part of device discovery or out-of-band changes) job fails with error org.hibernate.exception.DataException: Could not execute JDBC batch update for EX Series switches with ELS (EX92xx and EX43xx) if user has configured the login users with authentication type as ssh-dsa/ssh-ecdsa/ssh-rsa.

Workaround: Delete the authentication types ssh-dsa/ssh-ecdsa/ssh-rsa of login users and rediscover the devices from Network Director.

925272

If firewall in is disabled and enabled again in Junos Space, then file transfer through FTP and TFTP fails in the Zero Touch Provisioning setup. By default firewall is enabled on Junos Space.

Workaround: Execute following commands in space shell mode:
modprobe ip_conntrack_ftp
modprobe ip_conntrack_tftp

926625

Manage port admin state changes are not reflecting the exact state (UP/DOWN) in ND for the interfaces that are made UP/DOWN from ND if space is running in SSOR mode.

Workaround: None available at present.

914437

In Network Director, out of Sync devices are not listed in the Resynchronize Device page after upgrading from network Director Release 1.1 to Release 1.5. This issue is seen only when Space is in SSOR mode.

Workaround: Delete and Rediscover the devices after upgrading to Network Director Release 1.5.

928148

The Filter Functionality is not applicable for the Virtual View. However, if you have filters set in any other view - Logical, Location, Device- they are visible in the Virtual view also. When you clear the filters in the Virtual view, the filter is deleted from all other views as well.

Workaround: None available at present.

929451

In some instances, after installing Network Director you may not be able to discover devices.

Workaround: Restart the JBoss process by issuing the CLI command, service jboss restart and try discovering the devices.

859616

VSTP configurations deployed on a device through Device Common Settings profile fails, if you have more than 253 VLANs configured.

Workaround: Disable the configurations from the Device Common Settings profile and try again. Use the CLI to enable VSTP on the device.

889020

Deployment fails for a VLAN profile that has a routing instance when more than one VLAN is deployed on a routing instance at the device level.

Workaround: None available at present.

867666

Converting AUTO AP to configured AP is not deploying tags of all the local switching VLANs.

Workaround: Configure the VLAN tags using the CLI.

930202

Interfaces that are already part of other aggregated ethernet (ae) interfaces are listed in Port profile and FC Gateway Service profile assignment work flow. Assigning profiles to such interfaces will result in deployment failures.

Workaround: You must not assign Port profiles or FC Gateway Services profile to interfaces that are part of any other aggregated ethernet interfaces.

887143

When device discovery fails (due to various reasons), Network Director does not display the LLDP data related to virtual networks.

Workaround: LLDP data is resynchronized periodically—every 1 hour. The LLDP data that was missed during a device discovery failure situation, will be refreshed and updated in Network Director as part of the next resynchronization. Alternatively, you can initiate a manual vNetwork Resynchronization from the Manage vNetwork page.

899922

In Network Director running in SSOR mode, the status of the following devices will not change to out-of-sync for any out of band changes and Network Director will not be able to reconcile those out-of-band changes.

  • QFX3500 or QFX3600 devices running Junos OS Release 12.3X50-D30.2
  • EX4300 devices running Junos OS Release 13.2X50-D10.2
  • EX9200 devices running Junos OS Release 12.3R2

Workaround: Upgrade the QFX devices to Junos OS Release 12.3X50.D35. Upgrade EX4300 switches to Junos OS Release 13.2X50-D15.3 and EX9200 switches to Junos OS Release 13.2R1.

912243

Deploying a Fabric profile that has the same name, but a different fabric ID, as an existing one, from Network Director removes the interface association of the existing fabric profile from the device.

Workaround: Avoid deploying a Fabric profile that has the same name as an existing one on to the device.

914864

In Network Director, you cannot delete interface associated to Port profiles that are automatically created by Network Director as part of device discovery or out-of-band changes, if they are part of the interface-range stanza.

Workaround: None available at present.

924889

In Network Director, Enable DHCP Snooping check box in the VLAN profile page is shown as enabled by default for family ELS device.

Workaround: None available at present.

926631

In Network Director, L3-Interface IP address is not promoted if vlan.x is used instead of irb.x under "vlan l3-interface" stanza.

Workaround: Use L2NG irb.x naming convention instead of vlan.x.

917106

In a QFabric setup that has 2 Virtual Chassis, even though the node devices are connected to both the Virtual Chassis, Fabric Analyzer will be able to detect only the link to the master Virtual Chassis.

Workaround: None available at present.

919718

After sorting the columns in Node group page, editing the Node groups edits the wrong node group.

Workaround: Close and reopen the Manage Node Group page, and without sorting, select the node group that you want to edit and click Edit.

929278

The Data Center Port Profile Assignment page also displays EX4300 and EX9200 switches.

Workaround; Ensure that you do not assign profiles created for data center devices, to these EX Series switches.

901454

Reconciliation for a controller fails, with hibernate exception, when multiple controllers are reconciled together.

Workaround: Select a maximum of up to 2 controllers for each reconciliation task.

922660

For Manage LAG, deployment might fail for MC-LAG configurations if ICCP settings with LAG is not configured.

Workaround: Configure MC-LAG and ICCP settings and try again.

924433

In Fabric Analyzer, the connections between Directors will not be shown in Control Plane topology.

Workaround: None available at present.

925774

In the Edit Assignment page for port profile with family Routing, on clicking Device name > Define, the system prompts you to configure Authentication profile which is not required for port profile of family Routing.

Workaround: Ignore this message and proceed with the workflow by clicking the Next button

927258

You cannot delete a LAG associated with ICCP-LAG settings, unless the MC LAG is completely deleted.

Workaround: Delete all the MC-LAGs and then the deployment.

922191

The Manage ICCP Settings window, that opens from the Manage LAG and the Manage MC-LAG pages, accepts invalid IP addresses for Local IP, Peer IP, and Liveness detection backup peer IP fields. If you enter an invalid IP address in any of these fields, Network Director will not deploy this configuration on the device.

Workaround: You must enter a valid IP addresses in these fields or configure the correct values using the CLI and resynchronize the device.

924880

Network Director allows you to assign Fabric or FC Gateway Service profile to different TORs on the same QFabric, when you try to perform multiple assignments on the same QFabric.

Workaround: You must not try to assign the same Fabric or FC Gateway Service profile to different TORs on the QFabric using the assignment workflow multiple times.

867593

Access points are duplicated in the tree in some auto AP-related scenarios.

Workaround: None available at present.

867634

The access point count values might be different in the Equipment Summary By Type Detailed view and in the Equipment Summary By Type pie-chart view (shown in the Summary tab in Monitor mode at My Network level in Network Director).

Workaround: None available at present.

901930

You create an Authentication profile with the authentication method—captive portal or 802.1x—and include an Access profile to it, and deploy it using a Port profile. Network Director associates the Access profile to both captive portal and 802.1x even though you configured only one of these authentication methods while creating the Authentication profile.

Workaround: None available at present.

841306

Network Director does not support VVRP-Group configuration. If you change the unit number of the irb interface, then you must explicitly configure the vrrp-group configuration on the device for the new logical interface.

Workaround: None available at present.

924471

For Transit switches there is no way to configure extended DHCP relay and to enable https protocol from the Device Common Settings profile.

Workaround: Configure DHCP relay from the CLI.

885554

When you initiate a nonstop software upgrade (NSSU) for an EX8200 Virtual Chassis, all the member switches may not get upgraded. However, Network Director shows the job as successful even though all the member switches are not upgraded.

Workaround: None available at present.

901260

Nonstop software upgrade (NSSU) does not work as expected for QFabric systems.

Workaround: None available at present.

915897

For Campus Switching ELS devices, when trust DHCP is not selected from Network Director and deployed for a port, the DHCP security configurations are removed.

Workaround: None available at present.

908251

A WLC 2800 controller in an EX Series switch connection link is not displayed in the Show Device Connectivity page if only this controller is discovered..

Workaround: None available at present.

883384

Network Director might not display any data in the Fault and Monitor mode at the wireless controllers and wireless access point container levels in the Location and Device view.

Workaround: None available at present.

915318

Topology view does not display the STP link between a controller and an EX Series switch.

Workaround: Enable LLDP on all the interfaces to view the links.

915343

The Tooltip displays the IP address of JunosV Wireless LAN Controllers (JunosV WLCs) in reverse order.

Workaround: None available at present.

915087

Automatic resynchronization does not work for Qfabric devices.

Workaround: In NSOR mode, for every deploy from Network Director or out-of-band changes, QFabric device goes to out-of-sync. You must manually resynchronize the device each time, to make the device in sync.

911717

QFabric does not provide the IP address for the Director Group. As part of Topology discovery the CPE and the Director Group connections are discovered. As QFabric does not provide the IP address for the Director Group, the link is not shown in the floor plan.

Workaround: None available at present.

928198

Network Director uses Openstreetmap tiles and it support tiles through http. So while you work on the Topology view, you will see a warning about unsecure content.

Workaround: None available at present.

917395

Virtual view does not reflect the deletion of a virtual network unless the browser or view is refreshed.

Workaround: Press the Refresh icon in the bottom of the page, after the delete operation is done or select Virtual Networks from the View pane. Either of these action, refreshes the page.

929388

In virtual View->Show Connectivity-> Popup window is not of proper size.

Workaround: Resize the Show Connectivity page manually.

927708

This issue occurs when the Network Director view is set to LOCATION, DEVICE, or CUSTOM GROUP views. In the assign workflow of Device Common Settings and VLAN profiles for QFabric, Network Director displays the Nodes container (which contains TORs of the QFabric), which is not expected. So the user should select only the QFabric to proceed further instead of Individual TORs on the QFabric.

Workaround: On the Assign->Device Selection page, select Fabric container or Fabric->QFabric device model container or Fabric->QFabric device model->Qfabric device name container.

929576

Decommissioning the device-level association of a VLAN profile fails when the same VLAN is associated to a Port profile. So avoid decommissioning the VLAN profile when it is associated to a Port profile.

Workaround: For a successful deployment, clear the VLAN association from the Port profile.

930226

Port level attributes are not supported for ports that are members of a Port Group.

Workaround: In the Assignment workflow, remove the port and re-add the same port. Then you will get the option on the port to add port-level attributes.

930720

For Data Center Switching Non ELS devices, the Port to Assign window might not display the Family type as SWITCHING/ROUTING/FIBRE and the Mode as ACCESS/TRUNK/TAGGEDACCESS for some of the profiles of Qfabric devices, even when interfaces are configured with family and mode.

Workaround: View the family and mode in the Detail window of the respective profile.

930729

For Switching (EX), Campus Switching ELS and Data Center Switching Non ELS devices, in the assignment workflow, the Assign to Port window does not list VLAN information in the Vlans attribute column.

Workaround: Select the port profile and click the Details button to view the VLAN associated to the profile.

Monitor, Fault, and Report Mode Issues

926156

Fault and Monitoring data might not be displayed at the Outdoor Area level in Location View even though the devices associated with Outdoor Area have Monitoring and Fault data.

Workaround: None available at present.

929205

In the Find Endpoint Task, Verify Current Location in real time might not work for endpoints found in Qfabric.

Workaround: Select My Network in the View pane and click Refresh EndPoint in the Task pane. Network Director synchronizes all the endpoint details and updates the database.

862239

Auto-refresh of Monitoring widgets might stop for hours, because of which it might take hours for monitoring data to be updated.

Workaround: Navigate to any other mode—Build, Deploy, Report, or Fault, and then reopen the Monitor mode.

926912

When Qfabric node device alias is changed, Historical Monitoring data will be lost and duplicate port entries might be seen.

Workaround: Delete QFabric from Network Director and rediscover, to avoid duplicate entries.

911291

Alarms that already exist in a managed device, even before the device is assigned to any location, will not be shown in the Topology view

Workaround: None available at present.

924181

At My Network Level, port count shown in the Port Utilization Trend widget, might not be the actual used port count shown in the Port Status widget.

Workaround: None available at present.

866421

At Mobility Domain level, you may not be able to see any Monitoring or Fault data in the Monitor and Fault modes respectively.

Workaround: None available at present.

927301

At MyNetwork Level, the Session Trend Widget in the Monitor mode might not show any data.

Workaround: Session Trend data can be seen at the individual device level.

927659

Fabric Analyzer task for the Qfabric system might fail with the message—Operational RPC Command Results Failed to open netconf channel. This is due to a large number of netconf channels that are already open to the Qfabric system.

Workaround: Delete the QFabric and rediscover it from Network Director.

904683

Network Director might not display the Multicast Out value in Port statistics task in Traffic tab for the selected switch if there are more than 10 Multicast Out Packets/sec for the selected device.

Workaround: None available at present.

915108

Virtual View > Alarms for ESX servers are not aggregated and shown at Hosts folder level.

Workaround: None available at present.

928246

Current Sessions by Type widget might show an empty legend for WLCs that are running an MSS version that is earlier than 8.0.

Workaround: None available at present.

928694

In Internet Explorer 10 browser, the graphs displayed in the Monitor mode might not be plotted properly and at times it might have blank values in the X and Y axis.

Workaround: Use other browsers such as Internet Explorer 9, Google Chrome, or Mozilla Firefox or use the compatibility view in Internet Explorer 10.

928701

Details view of Resource Utilization Monitoring at Qfabric Node and Interconnect level might not show any data.

Workaround: None available at present.

929677

In Internet Explorer 9, clicking close [x] button on some of the windows might not close it.

Workaround: Press the Esc key to close the window.

918040

The L3 VLAN Statistics task in Monitoring mode will show No Data for ELS devices like EX4300 and EX9200.

Workaround: None available at present.

929857

For QFabric, in Custom Group view and Location view, monitors might show No Data at some of the container levels.

Workaround: Monitoring data can be accessed from the Logical view.

922285

The Find Endpoint task might show the Device Name field as empty, if there is no hostname configured on the switch.

Workaround: Configure a hostname on the EX Series switches and run the Refresh Endpoint task.

929918

Port Utilization Trend data might not be available at the Site, Building, Floor, Aisle, and Rack levels in Location view.

Workaround: Go to the individual device level of a device that is part of a Site, Building, Floor, Aisle, or Rack level to see the Port Utilization Trend data.

Network Director API Issues

904780

If your network includes an MX Series router and has multiple tenants set up with Layer 3 and Internet access services, each tenant might be able to View the Layer 3 traffic of other tenants on the MX Series router.

Workaround: None available at present.

905118

After you use Network Director API to activate services such as Layer 2 or Layer 3 connectivity on a switch, the access port on the switch is configured with the trunk port mode by default. As a result, the access port cannot communicate with physical (non-virtualized) servers that are part of the services. This issue does not affect virtualized servers.

Workaround: In a non-virtualized environment, configure the server port to send the Ethernet frames with VLAN tags:

  1. Find the VLAN ID from the NaasService-L2ConnectivityService
  2. Enter the following CLI command:

    sudo vconfig add interface-name VLAN-ID

    For example: sudo vconfig add eth1 22

  3. This creates a virtual interface eth1.22. Configure this virtual interface with an IP address and add routes as needed (similar to configuring any other physical interface).

905360

After you install the Network Director API, activating NaaS services might fail.

Workaround: Restart the JBoss process by issuing the CLI command, service jboss restart, and then activate NaaS services again.

918553

Reactivate with Layer 3 in QFabric fails in certain scenarios.

Workaround: None available at present.

929572

If you install Network Director and Network Director API after upgrading Junos Space network management platform to Release 13.1P5, the topology import for Network Director API might not work in some cases.

Workaround: Login to the SQL server and execute the command: alter table ServiceAccessPointPeer modify column peerL int(11);

930768

The Network Director API does not support clustered deployment across multiple Junos Space servers in this release.

Workaround: Deploy and use the Network Director API in a single Junos Space server environment only.

ND Mobile Issues

898154

ND Mobile when launched in Chrome Browser from an Apple iPad, might take around 2 mins to display login page.

Workaround: Use Safari browser for working on ND Mobile.

Known Limitations in Network Director Release 1.5

The known limitations in Network Director Release 1.5 include:

Related Documentation