You are here: Administration > Network Monitoring > Alarm > System Alarm.
You can enable system login alarm login classes. The configured Login Classes will display system alarms while logging in.
To create System Alarm Configuration:
Table 328: RPM Information Troubleshooting Options
Field | Function |
---|---|
Currently Running Tests | |
Graph | Click the Graph link to display the graph (if it is not already displayed) or to update the graph for a particular test. |
Owner | Configured owner name of the RPM test. |
Test Name | Configured name of the RPM test. |
Probe Type | Type of RPM probe configured for the specified test. Following are valid probe types:
|
Target Address | IP address or URL of the remote server that is being probed by the RPM test. |
Source Address | Explicitly configured source address that is included in the probe packet headers. If no source address is configured, the RPM probe packets use the outgoing interface as the source address, and the Source Address field is empty. |
Minimum RTT | Shortest round-trip time from the J Series device to the remote server, as measured over the course of the test. |
Maximum RTT | Longest round-trip time from the J Series device to the remote server, as measured over the course of the test. |
Average RTT | Average round-trip time from the J Series device to the remote server, as measured over the course of the test. |
Standard Deviation RTT | Standard deviation of round-trip times from the J Series device to the remote server, as measured over the course of the test. |
Probes Sent | Total number of probes sent over the course of the test. |
Loss Percentage | Percentage of probes sent for which a response was not received. |
Round-Trip Time for a Probe | |
Samples | Total number of probes used for the data set. The J Series device maintains records of the most recent 50 probes for each configured test. These 50 probes are used to generate RPM statistics for a particular test. |
Earliest Sample | System time when the first probe in the sample was received. |
Latest Sample | System time when the last probe in the sample was received. |
Mean Value | Average round-trip time for the 50-probe sample. |
Standard Deviation | Standard deviation of the round-trip times for the 50-probe sample. |
Lowest Value | Shortest round-trip time from the device to the remote server, as measured over the 50-probe sample. |
Time of Lowest Sample | System time when the lowest value in the 50-probe sample was received. |
Highest Value | Longest round-trip time from the J Series device to the remote server, as measured over the 50-probe sample. |
Time of Highest Sample | System time when the highest value in the 50-probe sample was received. |
Cumulative Jitter for a Probe | |
Samples | Total number of probes used for the data set. The J Series device maintains records of the most recent 50 probes for each configured test. These 50 probes are used to generate RPM statistics for a particular test. |
Earliest Sample | System time when the first probe in the sample was received. |
Latest Sample | System time when the last probe in the sample was received. |
Mean Value | Average jitter for the 50-probe sample. |
Standard Deviation | Standard deviation of the jitter values for the 50-probe sample. |
Lowest Value | Smallest jitter value, as measured over the 50-probe sample. |
Time of Lowest Sample | System time when the lowest value in the 50-probe sample was received. |
Highest Value | Highest jitter value, as measured over the 50-probe sample. |
Time of Highest Sample | System time when the highest jitter value in the 50-probe sample was received. |
System Alarm Configuration page appears.
To edit System Alarm Configuration:
See Table 328 for the options available for editing the System Alarm Configuration page.