Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All
     
     

    Monitoring the Redundancy Switchover History

    Purpose

    Display information about stateful SRP switchover history for the chassis.

    Action

    host1# show redundancy switchover-history
                                                 system
    SRP activation time      type       slot     uptime          running release
    -------------------   -----------   ----   ----------   -------------------------
    2004-07-26 10:44:25   cold-start     07       ---       L-07-25-60b1mrg-e.rel
    2004-07-25 20:58:57   warm-switch    06    0 00:15:08   L-07-25-60b1mrg-e.rel
    2004-07-25 20:53:41   warm-switch    07    0 00:09:51   L-07-25-60b1mrg-e.rel
    2004-07-25 20:44:43   cold-start     06       ---       L-07-25-60b1mrg-e.rel
    2004-07-25 19:32:01   cold-start     06       ---       L-07-25-60b1mrg-d.rel
    2004-07-25 18:58:01   warm-switch    06    0 00:12:01   L-07-25-60b1mrg-c.rel
    2004-07-25 18:51:56   cold-switch    07    0 00:05:56   L-07-25-60b1mrg-c.rel
    2004-07-25 18:46:54   cold-start     06       ---       L-07-25-60b1mrg-c.rel
    2004-07-25 17:44:48   warm-switch    06    0 00:14:32   L-07-25-60b1mrg-b.rel
    2004-07-25 17:31:07   cold-start     07       ---       L-07-25-60b1mrg-b.rel
    2004-07-25 16:05:08   cold-start     07       ---       L-07-25-60b1mrg-a.rel
    2004-07-24 23:25:09   warm-switch    07    0 16:27:03   L-07-24-60b1mrg-b.rel
    2004-07-24 23:18:23   cold-switch    06    0 16:20:17   L-07-24-60b1mrg-b.rel
    

    Meaning

    Table 1 lists the show redundancy switchover-history command output fields.

    Table 1: show redundancy switchover-history Output Fields

    Field Name

    Field Description

    SRP activation time

    Amount of time the SRP module has been active.

    type

    Type of switchover.

    slot

    Slot in which the SRP module resides.

    system uptime

    Amount of time the chassis has been operational.

    running release

    Release running on the SRP module at the time of the switchover.

     
     