Triggering ANCP OAM
You can provide an access-line test and rudimentary fault isolation capability for the B-RAS.
To trigger the access node to run a local loopback test on the specified interface:
- From Privileged Exec or User Exec mode, configure the
access node to run a local loopback test on the specified interface.host1#l2c oam interface atm 4/1.103
request succeeded0x503 : DSL line status showtime.DEFAULT RESPONSE - From Privilege Exec or User Exec mode, configure the
access node to run a local loopback test on the specified neighbor.host1#l2c oam neighbor accessnode_1002 end-user-id enduser_1002
request succeeded0x503 : DSL line status showtime.DEFAULT RESPONSE
Table 1 describes the l2c oam command fields.
Table 1: l2c oam Fields
Field Name | Field Description |
---|---|
Request status | Status of the OAM request (succeeded or failure) |
Response code | Code that returned with the OAM response |
DEFAULT RESPONSE | Response string (if any) that was included in the OAM response |