    Triggering ANCP Line Configuration

    You can trigger line configuration to the access node. Issuing this command sends a GSMP port management message to the access node. This message enables the B-RAS to configure a service profile name on an access loop.

    Note: Before issuing the l2c line-configuration command, a profile must already be configured locally on the access node.

    To trigger a GSMP port management message to the access node:

    • Issue the l2c line-configuration command in L2C Configuration mode.
      host1#l2c line-configuration interface atm 2/0.11 profile1

    There is no no version.

     

    Related Documentation

     

    Published: 2014-08-12