    t1 clock source

    Syntax

    t1 channel clock source { line | internal { module | chassis } }

    no t1 channel clock source

    Release Information

    Command introduced before JunosE Release 7.1.0.

    Description

    Determines which end of the T1 interface provides clocking. The no version uses the default value, line.

    Options

    • channel—One or more individual T1 channels, ranges of T1 channels, or combination of individual channels and ranges, in the range 1–28 (no spaces); for example, 3,7-15,19-13,27
    • line—Interface transmits data from a clock recovered from the line’s receive data stream
    • internal—Interface transmits data using its internal clock. You must specify one of the following for internal clocking:
      • module—Internal clock is from the line module itself
      • chassis—Internal clock is from the configured system clock

    Mode

    Controller Configuration

     
     