    Syntax

    [ no ] resource if-type { atm-active-sub-if | atm-sub-if | atm-vc | ip | ppp-link }
    { slot slot | system }
    threshold { falling fallingValue | hold-down-time holdDownTime | rising
    risingValue }

    Release Information

    Command introduced before JunosE Release 7.1.0.

    Description

    Specifies threshold values for specific interface types on a slot or systemwide basis. The no version sets the threshold parameter to its default value (for rising, 90% of the maximum value of the resource; for falling, 1% of the maximum value of the resource; for hold-down time, 300 seconds).

    Caution: Do not specify a falling value larger than the specified rising value; do not specify a rising value smaller than the specified falling value.

    Options

    • atm-active-sub-if—Configures active ATM subinterfaces
    • atm-sub-if—Configures both active and inactive ATM subinterfaces
    • atm-vc—Configures ATM virtual circuits
    • ip—Configures IP interfaces
    • ppp-link—Configures PPP link interfaces
    • slot—Number of the chassis slot in the range 0–2 (ERX310 model), 0–6 (ERX7xx models), 0–13 (ERX14xx models), 0–5 (E120 router), and 0-16 (E320 router)
    • For ERX7xx models, a number in the range 0–6; for ERX14xx models, a number in the range 0–13; for the ERX310 router, a number in the range 1–2; for the E120 router, a number in the range 0–5; for the E320 router, a number in the range 0–16
    • fallingValue—Falling threshold for the resource, in the range 0–4294967295
    • holdDownTime—Hold-down time for the resource, in the range 0–4294967295 seconds
    • risingValue—Rising threshold for the resource, in the range 0–4294967295

    Mode

    Global Configuration