    path ds1|e1 bert

    Syntax

    path pathChannel { ds1 | e1 } tributaryIdentifier bert
    pattern pattern interval time [ unframed ]

    no path pathChannel { ds1 | e1 } tributaryIdentifier bert

    Release Information

    Command introduced before JunosE Release 7.1.0.

    Description

    Enables bit error rate tests using the specified pattern at the DS1/E1 over SONET/SDH VT layer on channelized SONET and SDH interfaces. The no version stops the test that is running.

    Options

    • pathChannel—Number, in the range 1–2147483648, that identifies the path
    • tributaryIdentifier—Specifier for the tributary in the format
      pathChannel { ds1 | e1 } pathPayload/tributaryGroup/tributaryNumber
      • pathPayload—Payload number for the path; value is 1 for SONET and in the range 1–3 for SDH
      • tributaryGroup—Number, in the range 1–7, that identifies the group within the path
      • tributaryNumber—Number of the tributary within the tributary group; the value is in the range 1–4 if the tributary type is vt15 or tu11 and in the range 1–3 if the tributary type is tu12
    • pattern—One of the following test patterns:
      • 2^11—Pseudorandom test pattern, 2,047 bits long
      • 2^15—Pseudorandom test pattern, 32,767 bits long
      • 2^20-O153—Pseudorandom test pattern, 1,048,575 bits long
    • time—Duration of the test, in the range 1–1440 minutes
    • unframed—Test bit pattern occupies all bits on the link, overwriting the framing bits. If you do not specify this keyword, the test bit pattern occupies only T1/E1 payload bits.

    Mode

    Controller Configuration

    Published: 2014-08-18