Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    atm atm1483 auto-configure

    Syntax

    atm atm1483 auto-configure upperInterfaceType
    [ lockout-time { minValue maxValue | none } ]

    no atm atm1483 auto-configure upperInterfaceType [ lockout-time ]

    Release Information

    Command introduced before JunosE Release 7.1.0.

    Description

    Specifies one or more types of dynamic upper interface encapsulations that are accepted or detected by a dynamic ATM 1483 subinterface. Optionally, specifies the lockout time range for the encapsulation type. You can issue this command repeatedly in Profile Configuration mode to include autodetection of multiple upper interface encapsulation types within the base profile for a dynamic ATM 1483 subinterface. The no version terminates detection of the specified encapsulation type.

    Note: Encapsulation type lockout is available for bridged Ethernet, IP, PPP, and PPPoE encapsulation types.

    Options

    • upperInterfaceType—One of the following dynamic encapsulation types:
      • bridgedEthernet
      • ip
      • ppp
      • pppoe
    • minValue—Minimum lockout time in the range 1–86400 seconds (24 hours); default value is 1 second
    • maxValue—Maximum lockout time in the range 1–86400 seconds (24 hours); default value is 300 seconds (5 minutes)
    • none—Disables lockout for the specified dynamic encapsulation type

    Mode

    Profile Configuration

    Published: 2014-08-14