Monitoring System Timing Settings

Purpose

Display the timing settings and the operational status of the system timing. If a timing source fails, the system uses the next time source in the hierarchy, and a message appears in the system log at the warning level. If auto-upgrade is enabled, the system upgrades to a higher-priority timing source when one becomes available, and a message appears in the system log at the notice level.

Action

To display the timing settings and the operational status of the system timing:

host1#show timing
timing: tertiary (failover from primary) primary: external SC E1 (A) (ERROR) secondary: ds3 3/0 (ERROR) tertiary: internal SC oscillator (ok) auto-upgrade enabled

Meaning

Table 62 lists the show timing command output fields.

Table 62: show timing Output Fields

Field Name

Field Description

timing

Source of the timing signal

primary

Type and status of the primary timing signal

secondary

Type and status of the secondary timing signal

tertiary

Type and status of the tertiary timing signal

auto-upgrade

Status of the auto-upgrade parameter, which enables the system to revert to a higher-priority timing source after switching to a lower-priority timing source