revert-timer
Syntax
Hierarchy Level
- [edit protocols mpls],
- [edit protocols mpls label-switched-path lsp-name]
Release Information
Statement introduced in JUNOS Release 9.5 for EX Series switches.
Description
Specify the amount of time that a label switched path (LSP) must wait before traffic reverts to a primary path. If during this time the primary path experiences any connectivity problem or stability problem, the timer is restarted.
If you have configured a value of 0 seconds for the revert-timer statement and traffic is switched to the secondary path, the traffic remains on that path indefinitely. It is never switched back to the primary path unless you intervene.
Default
60 seconds
Options
-
seconds —Value in seconds.
- Range: 0 through 65,535 seconds
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.