ppp-options
Syntax
- ppp-options {
-
- chap {
- access-profile name;
- default-chap-secret name;
- local-name name;
- ;
- }
-
- dynamic-profile profile-name;
- lcp-max-conf-req number
- lcp-restart-timer milliseconds;
- loopback-clear-timer seconds;
- ncp-max-conf-req number
- ncp-restart-timer milliseconds;
-
- pap {
- access-profile name;
- default-pap-password password;
- local-name name;
- local-password password;
- ;
- }
- }
Hierarchy Level
- [edit interfaces interface-name],
- [edit interfaces interface-name unit logical-unit-number],
- [edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number]
Release Information
Statement introduced before JUNOS Release 7.4.
lcp-restart-timer statement introduced in JUNOS Release 8.1.
ncp-restart-timer statement introduced in JUNOS Release 8.1.
loopback-clear-timer statement introduced in JUNOS Release 8.5.
dynamic-profile statement introduced in JUNOS Release 9.5.
Description
On interfaces with PPP encapsulation, configure PPP-specific interface properties.
For ATM2 IQ interfaces only, you can configure CHAP on the logical interface unit if the logical interface is configured with one of the following PPP over ATM encapsulation types:
- atm-ppp-llc—PPP over AAL5 LLC encapsulation.
- atm-ppp-vc-mux—PPP over AAL5 multiplex encapsulation.
The remaining statements are explained separately.
Usage Guidelines
See Configuring the PPP Challenge Handshake Authentication Protocol.
Required Privilege Level
interface—To view this statement in the configuration.