Alarm Index
|
Alarm identifier.
|
All levels
|
State
|
State of the alarm or event entry:
Alarms:
- active—Entry is fully configured and activated.
- falling threshold crossed—Value of the
variable has crossed the lower threshold limit.
- rising threshold crossed—Value of the variable
has crossed the upper threshold limit.
- under creation—Entry is being configured
and is not yet activated.
- startup—Alarm is waiting for the first
sample of the monitored variable.
- object not available—Monitored variable
of that type is not available to the SNMP agent.
- instance not available—Monitored variable's
instance is not available to the SNMP agent.
- object type invalid—Monitored variable
is not a numeric value.
- object processing errored—An error occurred
when the monitored variable was processed.
- unknown—State is not one of the above.
Events:
- active—Entry has been fully configured
and activated.
- under creation—Entry is being configured
and is not yet activated.
- unknown—State is not one of the above.
|
All levels
|
Variable name
|
Name of the SNMP object instance
being monitored.
|
All levels
|
Event Index
|
Event identifier.
|
All levels
|
Type
|
Type of notification made when
an event is triggered. It can be one of the following:
- log—A system log message is generated and
an entry is made to the log table.
- snmptrap—An SNMP trap is sent to the configured
destination.
- log and trap—A system log message is generated,
an entry is made to the log table, and an SNMP trap is sent to the
configured destination.
- none—Neither log nor trap will be sent.
|
detail
|
Last Event
|
Date and time of the last event.
It has the format yyyy-mm-dd hh:mm:ss timezone.
|
brief
|
Community
|
Identifies the trap group used
for sending the SNMP trap.
|
detail
|
Variable OID
|
Object ID to which the variable
name is resolved. The format is x.x.x.x.
|
detail
|
Sample type
|
Method of sampling the monitored
variable and calculating the value to compare against the upper and
lower thresholds. It can have the value of absolute value or delta value.
|
detail
|
Startup alarm
|
Alarm that might be sent when this
entry is first activated, depending on the following criteria:
- Alarm is sent when one of the following situations exists:
- Value of the alarm is above or equal to the rising threshold
and the startup type is either rising alarm or rising
or falling alarm.
- Value of the alarm is below or equal to the falling threshold
and the startup type is either falling alarm or rising
or falling alarm.
- Alarm is not sent when one of the
following situations exists:
- Value of the alarm is above or equal to the rising threshold
and the startup type is falling alarm.
- Value of the alarm is below or equal to the falling threshold
and the startup type is rising alarm.
- Value of the alarm is between the thresholds.
|
detail
|
Owner
|
Name of the entry configured by
the user. If the entry was created through the CLI, the owner has monitor prepended to it.
|
detail
|
Creator
|
Mechanism by which the entry was
configured (CLI or SNMP).
|
detail
|
Sample interval
|
Time period between samples (in
seconds).
|
detail
|
Rising threshold
|
Upper limit threshold value configured
by the user.
|
detail
|
Falling threshold
|
Lower limit threshold value configured
by the user.
|
detail
|
Rising event index
|
Event triggered when the rising
threshold is crossed.
|
detail
|
Falling event index
|
Event triggered when the falling
threshold is crossed.
|
detail
|
Current value
|
Current value of the monitored
variable in the most recent sample interval.
|
detail
|