Command introduced before JUNOS Release 7.4.
sfc option for the TX Matrix Plus router introduced in JUNOS Release 9.6.
Display information about the conditions that have been configured to trigger alarms.
none — (TX Matrix and TX Matrix Plus routers only) On the TX Matrix router, display information about the conditions that have been configured to trigger alarms on the TX Matrix router and its attached T640 routers. On the TX Matrix Plus router, display information about the conditions that have been configured to trigger alarms on the TX Matrix Plus router and its attached T1600 routers.
lcc number — (TX Matrix and TX Matrix Plus routers only) (Optional) On the TX Matrix router, show information about a specified T640 router (or line-card chassis) that is connected to the TX Matrix router. On the TX Matrix Plus router, show information about a specified T1600 router (or line-card chassis) that is connected to the TX Matrix Plus router. Replace number with a value from 0 through 3.
scc — (TX Matrix router only) (Optional) Show information about the TX Matrix router (or switch-card chassis).
sfc number — (TX Matrix Plus router only) (Optional) Show information about the TX Matrix Plus router (or switch-fabric chassis). Replace number with 0.
You cannot clear the alarms for chassis components. Instead, you must remedy the cause of the alarm. When a chassis alarm is lit, it indicates that you are running the router in a manner that we do not recommend.
You can manually silence external devices connected to the alarm relay contacts by pressing the alarm cutoff button, located on the craft interface. Silencing the device does not remove the alarm messages from the display (if present on the router) or extinguish the alarm LEDs. In addition, new alarms that occur after you silence an external device reactivate the external device.
view
Table 39 lists the output fields for the show chassis alarms command. Output fields are listed in the approximate order in which they appear.
Table 39: show chassis alarms Output Fields
Field Name |
Field Description |
|---|---|
Alarm time |
Date and time the alarm was first recorded. |
Class |
Severity class for this alarm: Minor or Major. |
Description |
Information about the alarm. |
show chassis alarms (Alarms Active)
user@host> show chassis alarms3 alarms are currently active Alarm time Class Description 2000-02-07 10:12:22 UTC Major fxp0: ethernet link down 2000-02-07 10:11:54 UTC Minor YELLOW ALARM - PEM 1 Removed 2000-02-07 10:11:03 UTC Minor YELLOW ALARM - Lower Fan Tray Removed
show chassis alarms (No Alarms Active)
user@host> show chassis alarmsNo alarms are currently active
show chassis alarms (Alarms Active on a TX Matrix Router)
user@host> show chassis alarms scc-re0: -------------------------------------------------------------------------- 8 alarms currently active Alarm time Class Description 2004-08-05 18:43:53 PDT Minor LCC 0 Minor Errors 2004-08-05 18:43:53 PDT Minor SIB 3 Not Online 2004-08-05 18:43:52 PDT Major SIB 2 Absent 2004-08-05 18:43:52 PDT Major SIB 1 Absent 2004-08-05 18:43:52 PDT Major SIB 0 Absent 2004-08-05 18:43:33 PDT Major LCC 2 Major Errors 2004-08-05 18:43:28 PDT Major LCC 0 Major Errors 2004-08-05 18:43:05 PDT Minor LCC 2 Minor Errors lcc0-re0: -------------------------------------------------------------------------- 5 alarms currently active Alarm time Class Description 2004-08-05 18:43:53 PDT Minor SIB 3 Not Online 2004-08-05 18:43:49 PDT Major SIB 2 Absent 2004-08-05 18:43:49 PDT Major SIB 1 Absent 2004-08-05 18:43:49 PDT Major SIB 0 Absent 2004-08-05 18:43:28 PDT Major PEM 0 Not OK lcc2-re0: -------------------------------------------------------------------------- 5 alarms currently active Alarm time Class Description 2004-08-05 18:43:35 PDT Minor SIB 3 Not Online 2004-08-05 18:43:33 PDT Major SIB 2 Absent 2004-08-05 18:43:33 PDT Major SIB 1 Absent 2004-08-05 18:43:33 PDT Major SIB 0 Absent 2004-08-05 18:43:05 PDT Minor PEM 1 Absent
show chassis alarms (Backup Routing Engine)
user@host> show chassis alarms2 alarms are currently active Alarm time Class Description 2005-04-07 10:12:22 PDT Minor Host 1 Boot from alternate media 2005-04-07 10:11:54 PDT Major Host 1 compact-flash missing in Boot List
show chassis alarms (Alarms Active on a TX Matrix Plus Router)
user@host> show chassis alarms sfc0-re0: -------------------------------------------------------------------------- 22 alarms currently active Alarm time Class Description 2009-05-06 17:33:51 PDT Major LCC 0 Major Errors 2009-05-06 17:33:49 PDT Minor Check SIB F13 0 2009-05-06 17:33:49 PDT Minor SIB F13 0 LOL 2009-05-06 17:33:47 PDT Major SIB F2S 4/6 Absent 2009-05-06 17:33:47 PDT Major SIB F2S 4/4 Absent 2009-05-06 17:33:47 PDT Major SIB F2S 4/2 Absent 2009-05-06 17:33:47 PDT Major SIB F2S 4/0 Absent 2009-05-06 17:33:47 PDT Major SIB F2S 3/6 Absent 2009-05-06 17:33:47 PDT Major SIB F2S 3/4 Absent 2009-05-06 17:33:47 PDT Major SIB F2S 3/2 Absent 2009-05-06 17:33:47 PDT Major SIB F2S 3/0 Absent 2009-05-06 17:33:47 PDT Major SIB F2S 2/6 Absent 2009-05-06 17:33:47 PDT Major SIB F13 12 Absent 2009-05-06 17:33:47 PDT Major SIB F13 11 Absent 2009-05-06 17:33:47 PDT Major SIB F13 9 Absent 2009-05-06 17:33:47 PDT Major SIB F13 8 Absent 2009-05-06 17:33:47 PDT Major SIB F13 7 Absent 2009-05-06 17:33:47 PDT Major SIB F13 6 Absent 2009-05-06 17:33:47 PDT Major SIB F13 4 Absent 2009-05-06 17:33:47 PDT Major SIB F13 3 Absent 2009-05-06 17:32:40 PDT Minor LCC 0 Minor Errors 2009-05-06 17:31:49 PDT Minor PEM 1 Absent lcc0-re0: -------------------------------------------------------------------------- 5 alarms currently active Alarm time Class Description 2009-05-06 17:33:53 PDT Minor Check SIB 0 2009-05-06 17:33:51 PDT Major SIB_L - Fan Revision mismatch 2009-05-06 17:33:49 PDT Minor SIB 0 Fbr Bndls 2009-05-06 17:33:49 PDT Minor SIB 0 LOL 2009-05-06 17:31:58 PDT Minor PEM 1 Absent