[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

request chassis sib

Syntax

request chassis sib (offline | online) slot slot-number

Syntax (TX Matrix Router)

request chassis sib (all-chassis | lcc number | scc) (offline | online) slot slot-number
(start-receiver number | stop-receiver number)

Syntax (TX Matrix Plus Router)

request chassis sib (all-chassis | all-lcc | f13 slot-number | f2s slot-number | lcc number  | (offline | online) slot slot-number

Release Information

Command introduced before JUNOS Release 7.4.

f13 and f2s options for the TX Matrix Plus router introduced in JUNOS Release 9.6.

Description

(M320 routers and T Series routers only) Control the operation of the specified Switch Interface Board (SIB).

Options

all-chassis — (TX Matrix and TX Matrix Plus routers only) Control the operation of the SIB in the specified slot on the TX Matrix router and on all T640 routers connected to the TX Matrix router. On a TX Matrix Plus router, control the operation of the SIB in the specified slot on the TX Matrix Plus router and on all T1600 router connected to the TX Matrix Plus router.

all-lcc — (TX Matrix Plus routers only) Control the operation of the SIB on all T1600 routers connected to the TX Matrix Plus router.

f13 slot-numberControl the operation of F13 SIBs. Replace slot-number with a value from 0 through 15.

f2s slot-numberControl the operation of F2 SIBs. Replace slot-number with a value from 0 through 15.

lcc number(TX Matrix and TX Matrix Plus routers only) On a TX Matrix router, the T640 router (or line-card chassis) that is connected to the TX Matrix router. On a TX Matrix Plus router, the T1600 router (or line-card chassis) and TX Matrix Plus that is connected to the TX Matrix Plus router. Replace number with a value from 0 through 3.

scc — (TX Matrix router only) TX Matrix router (or switch-card chassis) on a routing matrix.

offline — Take the SIB offline.

online — Bring the SIB online.

slot slot-numberSIB slot number. For the T320 router, replace slot-number with a value from 0 through 2. For the T640 router, TX Matrix router, and T1600 router in a routing matrix, replace slot-number with a value from 0 through 4. On a TX Matrix Plus router,replace slot-number with a value from 0 through 15 for the F13 SIBs. For the F2 SIBs in a TX Matrix Plus router, replace slot-number with m/n where m is form 0 through 4 and n is 0, 2, 4 or 6.

start-receiver number(TX Matrix and TX Matrix Plus routers only) Start the SIB optical receiver. Replace  number with a value from 0 through 3.

stop-receiver number(TX Matrix and TX Matrix Plus routers only) Stop the SIB optical receiver.Replace number with a value from 0 through 3.

Required Privilege Level

maintenance

Related Topics

show chassis sibs

List of Sample Output

request chassis sib

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis sib

user@host> request chassis sib slot 0 online
Online initiated, use "show chassis sibs" to verify