Contents]
[
Prev]
[
Next]
[
Index]
[
Report an Error]
temps
Syntax
temps -T target
Release Information
Command supported by JUNOS Release 9.1
and later.
Description
(JCS 1200 platform only) Show temperature information
(in degrees Fahrenheit) for components in the JCS chassis. This information
is useful for viewing current temperature values and temperature threshold
settings.
Options
-T target—Specify
the target of the temps command. Valid targets for this command
are:
- system:blade[x]—Specify
a Routing Engine as the command target. Replace x with the Routing Engine slot number (1 through 12).
- system:switch[x]—Specify
a JCS switch module as the command target. Replace x with the switch number (1 or 2).
- system:mm[x]—Specify
a JCS management module as the command target. Replace x with the primary management module number (1 or 2).
Required Privilege Level
operator (display)
Related Topics
List of Sample Output
temps (Routing Engine)
temps (JCS Management Module)
Output Fields
Table 28 lists the output
fields for the temps command. Output fields are listed in
the approximate order in which they appear.
Table 28: temps Output Fields
Field Name
|
Field Description
|
Value
|
Current temperature (in degrees Fahrenheit) of the component.
|
Warning
|
Temperature at which a warning
message occurs.
|
Reset
|
Temperature at which the component
will reset.
|
Hysteresis
|
The amount the temperature must decrease below the Warning
threshold before the warning is cleared.
|
Sample Output
temps (Routing Engine)
system> temps -T system:blade[3]Component Value Warning Reset Hysteresis
CPU1 38.00 85.00 95.00 (7.00)
CPU2 35.00 85.00 95.00 (7.00)
temps (JCS Management Module)
system> temps -T system:mm[2]Component Value Warning Reset Hysteresis
MM Ambient 43.00 60.00 55.00 (5.00)
[
Contents]
[
Prev]
[
Next]
[
Index]
[
Report an Error]