fuelg -T system:mm[x] <domain> <-qm (off | on)>
Command supported by JUNOS Release 9.1 and later.
(JCS management module CLI) Display or configure power domain information for power supplies on the JCS 1200 platform.
-T system:mm[x]—Specify the JCS management module as the target of the command. Replace x with a value of 1 or 2.
domain—(Optional) Display information for a specific power domain. Replace domain with pd1 (power domain 1) or pd2 (power domain 2). By default, power domain information is displayed for both power domains.
The JCS 1200 Platform has two power domains. Power domain 1 supports all JCS modules and slots (bays) 1 through 6. Power domain 1 uses power supply modules 1 and 2. Power domain 2 supports slots 7 through 12 and uses power supply modules 3 and 4.
-qm (on | off)—(Optional) Specify a thermal event response (quiet mode):
supervisor (configure)
operator (display)
Table 26 lists the output fields for the fuelg command. Output fields are listed in the approximate order in which they appear.
Table 26: fuelg Output Fields
system> fuelg –T system:mm[1]Power Domain 1
— — — — — — — —
Status: Power domain status is good.
Modules:
Bay 1: 2000
Bay 2: 2000
Power Budget: 3200
Reserved Power: 400
Remaining Power: 2800
Power in Use: 400
Power Domain 2
— — — — — — — —
Status: Power domain status is good.
Modules:
Bay 3: 1800
Bay 4: 1800
Power Budget: 2880
Reserved Power: 0
Remaining Power: 2880
Power in Use: 0
system> fuelg –T system:mm[1] -qm offOK